首页> 外文期刊>The Journal of arthroplasty >The lack of correlation between radiographic findings and cartilage integrity.
【24h】

The lack of correlation between radiographic findings and cartilage integrity.

机译:影像学检查结果与软骨完整性之间缺乏相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

Total knee arthroplasty is a common treatment of osteoarthritis, although unicompartmental knee arthroplasties are frequently used to retain unaffected compartments. Joint space width (JSW) is a major factor in determining treatment. We examined the relationship between JSW and cartilage quality in 60 patients undergoing total knee arthroplasty to assess its accuracy in representing cartilage degradation. Radiographic JSW was recorded, whereas the unaffected compartment of each tibial plateau was examined postoperatively using Collins, Mankin, and Kellgren and Lawrence scores. No correlation was seen between visual or histologic grading and JSW. Histology more accurately represented cartilage quality, yet it is impractical to obtain preoperatively; thus, JSW is the main mode of assessment. However, using JSW solely to indicate unicompartmental knee arthroplasty may overlook disease in apparently unaffected compartments.
机译:全膝关节置换术是骨关节炎的常见治疗方法,尽管单室膝关节置换术通常用于保留不受影响的隔室。关节间隙宽度(JSW)是决定治疗的主要因素。我们检查了60名接受全膝关节置换术的患者的JSW与软骨质量之间的关系,以评估其代表软骨退化的准确性。记录了影像学JSW,而术后使用Collins,Mankin,Kellgren和Lawrence评分对每个胫骨平台未受影响的部位进行检查。视觉或组织学分级与JSW之间没有相关性。组织学更准确地表示软骨质量,但术前获取是不切实际的。因此,JSW是主要的评估方式。但是,仅使用JSW表示单室膝关节置换术可能会忽略表面未受影响的隔室中的疾病。