Complete 180 degrees rotatory dislocation in a mobile-bearing knee prothesis.

机译:可移动的膝关节假体可完成180度旋转脱位。

获取原文
获取原文并翻译 | 示例
       

摘要

Dislocation of the rotator platform in mobile-bearing total knee arthroplasty is a well-documented, albeit uncommon, phenomenon. A review of the literature has revealed multiple case reports describing spin out to 90 degrees or complete extrusion of the polyethylene component. Closed reduction may be attempted in the acute presentation followed by revision if instability persists. We present a case of a 57-year-old woman who had a partial rotatory subluxation of her polyethylene component and underwent closed reduction resulting in a full 180 degrees spinout. To our knowledge, this has not been described in the literature and should be considered as a possibility after closed reduction attempts. She was treated successfully with open exploration and poly exchange using a larger component.
机译:可动的全膝关节置换术中旋转平台的脱位是有据可查的,尽管不常见。文献回顾显示,有多个病例报告描述了旋出至90度或完全挤出聚乙烯组分的情况。如果不稳定性持续存在,可以尝试在急性表现中进行闭合复位,然后进行翻修。我们介绍了一个57岁的妇女,她的聚乙烯成分部分旋转半脱位,并进行了闭合复位,导致180度旋转。据我们所知,文献中没有对此进行描述,应该将其视为封闭还原尝试之后的一种可能性。她通过使用更大的成分进行的开放勘探和聚交换成功地得到了治疗。