Eight- to ten-year clinical and radiographic outcome of a porous tantalum monoblock acetabular component.

机译:多孔钽整体式髋臼组件的八至十年临床和影像学结果。

获取原文
获取原文并翻译 | 示例
           

摘要

In a prospective study, the authors used a porous tantalum monoblock acetabular component for primary total hip arthroplasty between November 1997 and June 1999. A total of 156 consecutive primary total hip arthroplasty were done in 143 patients younger than 75 years. A total of 151 hips had a follow-up time from 8 to 10 years. The average preoperative total Harris hip score of 44.0 +/- 13.8 increased to 97.0 +/- 6.2 at the latest follow-up. The average preoperative Oxford hip score of 43.3 +/- 6.5 improved to 13.9 +/- 2.3 at the latest follow-up. Radiographic evaluation including the Ein-Bild-Rontgen-Analyse (EBRA) digital system showed no radiographic evidence of gross polyethylene wear, progressive radiolucencies, osteolytic lesions, acetabular fracture, or component subsidence. There were 7 (4.5%) postoperative complications all unrelated to the acetabular component.
机译:在一项前瞻性研究中,作者在1997年11月至1999年6月之间使用多孔钽单嵌段髋臼组件进行了原发性全髋关节置换术。在143名年龄小于75岁的患者中共进行了156次连续的原发性全髋关节置换术。总共151个髋关节的随访时间为8至10年。在最近的随访中,术前平均Harris总髋关节评分为44.0 +/- 13.8,增至97.0 +/- 6.2。在最近的随访中,术前牛津髋关节的平均评分为43.3 +/- 6.5,提高到13.9 +/- 2.3。包括Ein-Bild-Rontgen-Analyse(EBRA)数字系统在内的射线照相评估显示,没有射线照相证据表明聚乙烯总磨损,进行性射线透透,溶骨性病变,髋臼骨折或下陷。有7例(4.5%)术后并发症均与髋臼组件无关。