Results and complications of the low contact stress knee prosthesis.

机译:低接触应力膝关节假体的结果和并发症。

获取原文
获取原文并翻译 | 示例
           

摘要

We present the midterm results and complications of 101 low contact stress total knee replacements performed in 94 patients and reviewed at an average follow-up of 5.2 years (range, 4-8 years). The mean age at the time of surgery was 66 years (range, 53-76 years). Meniscal bearings were used in 83 knees and a rotating platform in the remaining 18 cases; cemented fixation was used only for 16 tibial components. At most recent follow-up, average knee and function scores were 93 and 78 points. None of the knees was revised because of loosening. Five knees showed distal femoral stress shielding. Complications included infection, supracondylar fracture, patellar component dislodgment, meniscal dislocation (2 cases), catastrophic wear of polyethylene, and progressive osteolysis (2 cases).
机译:我们介绍了94例患者进行的101例低接触应力全膝关节置换术的中期结果和并发症,平均随访时间为5.2年(4-8年)。手术时的平均年龄为66岁(范围53-76岁)。在其余18例中,半月板轴承用于83个膝盖和旋转平台。骨水泥固定仅用于16个胫骨组件。在最近的随访中,平均膝关节和功能评分分别为93和78分。膝盖没有因松动而被翻修。五个膝盖显示远端股骨应力屏蔽。并发症包括感染,con上骨折,pa骨移位,半月板脱位(2例),聚乙烯的严重磨损和进行性溶骨(2例)。