首页> 外文期刊>The Journal of arthroplasty >Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique.
【24h】

Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique.

机译:随机对照试验比较了使用计算机导航和传统技术进行X线摄影术总膝关节置换术植入物的位置。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study is to assess the radiological outcome of conventional techniques versus computer-navigated surgery for total knee arthroplasty. Ninety patients with knee arthritis were prospectively randomized into 3 groups: conventional technique: extramedullary (EM) and intramedullary (IM) tibia guide versus computer navigation surgery (CAS). Two surgeons performed all procedures. Standardized long leg coronal and sagittal x-rays were evaluated by a blinded assessor. Our results showed that CAS had greater consistency and accuracy in implant placement. In the coronal view, 93.3% in the CAS group had better outcomes compared with EM (73.4%) and IM (60.0%). In the sagittal axis, 90.0% CAS also had better outcomes compared with EM (63.3%) and IM (76.7%). Computer-navigated total knee arthroplasty helps increase accuracy and reduce "outliers" for implant placement.
机译:这项研究的目的是评估常规技术与计算机导航手术进行全膝关节置换的放射学结果。将90例膝关节炎患者随机分为3组:常规技术:髓外(EM)和髓内(IM)胫骨指南与计算机导航手术(CAS)。两名外科医生执行了所有程序。盲人评估者对标准的长腿冠状和矢状X线片进行了评估。我们的结果表明,CAS在种植体植入方面具有更高的一致性和准确性。在冠状动脉方面,CAS组93.3%的结果优于EM(73.4%)和IM(60.0%)。在矢状轴上,CAS的90.0%也比EM(63.3%)和IM(76.7%)更好。计算机导航的全膝关节置换术有助于提高准确性,并减少植入物放置的“异常值”。