We report the dislocation of 6 liners out of the metal backing shells of Harris Galante II cementless total hip prostheses implanted between 1993 and 1996. The time between primary implantation and failure varied from 46 to 95 months. The dislocations were probably the result of suboptimal mechanical fixation of the polyethylene liner in the shell compounded by suboptimal positioning of the acetabular component. In 5 cases, both the metal backing and the liner were revised because of broken tines. In one case, only the liner was exchanged.
机译:我们报道了从1993年至1996年间植入的Harris Galante II非骨水泥全髋关节假体的金属背衬中脱位了6个衬里。从初次植入到失败的时间从46个月到95个月不等。错位可能是由于聚乙烯内衬在髋臼中的机械固定不理想而导致的,而髋臼组件的定位欠佳。在5种情况下,由于尖齿断裂,金属衬板和衬板都进行了修整。在一种情况下,仅更换了衬管。