Beginning in December 1995, 193 patients (195 hips) were enrolled into this prospective, randomized, controlled multicenter investigational device exemption study. Ninety-eight patients (99 hips) with 46 polyethylene liners and 53 metal liners had minimum 5-year follow-up (mean, 5.7 years). Average follow-up, Harris hip score improvement, and radiographic analysis were not statistically different between groups. No stress shielding or osteolysis was observed in either group. Three polyethylene liners and no metal liners had acetabular radiolucencies <1 mm in 1 or more zones. There have been no device-related complications, no acetabular revisions performed, and none pending in either group. Based on these mid-term results, the authors conclude that a metal-on-metal articulation represents a viable alternative in young, high-demand, active patients.
机译:从1995年12月开始,有193名患者(195髋)被纳入这项前瞻性,随机,对照的多中心研究性器械豁免研究。 98名患者(99髋)有46个聚乙烯衬里和53个金属衬里,至少进行了5年随访(平均5.7年)。各组之间的平均随访,Harris髋关节评分改善和影像学分析无统计学差异。两组均未观察到应力屏蔽或骨溶解。 3个聚乙烯衬管和无金属衬管在1个或多个区域中的髋臼放射线透射率小于1 mm。两组均未发生与器械相关的并发症,未进行髋臼翻修,也没有待决。基于这些中期结果,作者得出结论,金属对金属的关节连接是年轻,高需求,活跃患者的可行选择。