首页> 外文期刊>The Journal of arthroplasty >Minimal 11-year follow-up of extensively porous-coated stems in femoral revision total hip arthroplasty.
【24h】

Minimal 11-year follow-up of extensively porous-coated stems in femoral revision total hip arthroplasty.

机译:股骨翻修全髋关节置换术中广泛多孔涂层的茎的最少11年随访。

获取原文
获取原文并翻译 | 示例

摘要

Between 1984 and 1989, 188 consecutive femoral revision surgeries were performed. Eighteen patients died or were lost to follow-up, and the remaining 170 patients were followed for 11 to 16 years (mean, 14.2 years). Radiographic evidence of a bone ingrown stem was present in 82% of the hips, stable fibrous fixation was present in 14% of the hips, and 4% of the hips were unstable. Six stems were revised to a larger, fully coated cementless implant. Proximal femoral osteolysis was seen in 23% of femora but was limited to Gruen zones 1 and 7. No diaphyseal osteolysis was seen. The overall mechanical failure rate in this series was 4.1%. Failure of fixation correlated highly with extent of bone loss present at the time of surgery. On the basis of the radiographic and clinical results at a mean follow-up of 14.2 years, we recommend the use of extensively coated femoral stems in revision hip arthroplasty.
机译:在1984年至1989年之间,连续进行了188次股骨翻修手术。 18位患者死亡或失去随访,其余170位患者随访11至16年(平均14.2年)。 82%的髋部存在放射状的骨骼向内生长,14%的髋部存在稳定的纤维固定,4%的髋关节不稳定。将六个茎修改为更大的,完全涂层的非骨水泥植入物。在23%的股骨中可见股骨近端骨溶解,但仅限于Gruen 1区和7区。未见骨干骨溶解。该系列的总体机械故障率为4.1%。固定失败与手术时出现的骨丢失程度高度相关。根据平均随访14.2年的影像学和临床结果,我们建议在翻修髋关节置换术中使用广泛覆盖的股骨柄。