We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. (C) 2016 Elsevier Inc. All rights reserved.
机译:我们评估了陶瓷-陶瓷全髋关节置换术中陶瓷轴承断裂后,随着轴承更换为聚乙烯/金属-聚乙烯(MoP)的再手术的短期至中期结果。更换MoP后,治疗了9例第三代陶瓷轴承骨折(6个头部和3个衬套)。再次手术的平均年龄为52.7岁。平均随访时间为4.3年。在随访过程中,3个内衬骨折的髋关节中有2个和6个头部骨折的髋部中有1个显示出金属化病的放射学体征和血清铬水平升高。对患有金属病的髋关节进行了重新手术,将轴承更换为陶瓷头。一只衬垫破裂的髋关节有假体周围感染。脱位发生在3髋。根据我们的经验,对于全髋关节置换术中陶瓷轴承断裂,不建议将轴承更换为MoP。 (C)2016 Elsevier Inc.保留所有权利。