Management of an infected hip prosthesis typically requires that all associated cement be removed. In the absence of gross mantle loosening, the surgeon frequently resorts to intraoperative radiographs to assess the completeness of removal. For this reason, we undertook a study to determine limits of detection of retained cement by routine radiography. Polymethyl methacrylate bone-cement beads (Simplex-P; Stryker-Howmedica-Osteonics, Allendale, NJ) were fashioned into graduated sizes and placed within cadaver medullary canals using 2 different methods. Standard radiographic images were obtained. Individually and independently, we viewed these images and proposed the limit of resolution to be 2.4 to 3.2 mm. It is difficult to remove all cement based on radiographs alone. These results suggest a need to use techniques that permit visualization of the canal to ensure adequate cement removal.
机译:处理感染的髋关节假体通常需要去除所有相关的骨水泥。在没有明显的外套膜松动的情况下,外科医生经常求助于术中X光片以评估切除的完整性。因此,我们进行了一项研究,以确定常规放射线照相法检测残留水泥的极限。将聚甲基丙烯酸甲酯骨水泥珠(Simplex-P; Stryker-Howmedica-Osteonics,Allendale,NJ)制成带刻度的大小,并使用2种不同的方法放置在尸体髓管内。获得标准放射线图像。我们单独和独立地查看了这些图像,并建议将分辨率限制为2.4到3.2 mm。仅根据射线照相很难去除所有的水泥。这些结果表明需要使用允许对运河进行可视化以确保充分去除水泥的技术。