首页> 外文期刊>The Journal of arthroplasty >A retrospective clinical and radiographic review of 173 hydroxyapatite-coated screw cups with 5- to 10-year follow-up, showing low revision rates for fixation failure.
【24h】

A retrospective clinical and radiographic review of 173 hydroxyapatite-coated screw cups with 5- to 10-year follow-up, showing low revision rates for fixation failure.

机译:回顾性临床和影像学检查显示,对173个羟基磷灰石涂层螺旋杯进行了5至10年的随访,结果显示修复失败的修订率较低。

获取原文
获取原文并翻译 | 示例
           

摘要

We reviewed the midterm results of 173 hydroxyapatite-coated screw cups. The average follow-up was 6.5 years (range, 5-9 years). The follow-up rate was 93%. Patients were assessed using the Merle D'Aubigne-Postel clinical scoring scale and by radiographic review. Two patients had revision surgery for recurrent dislocation (1.2%), 3 patients were revised for aseptic loosening (1.7%), 1 patient underwent revision surgery because of deep prosthetic infection (0.6%), and 2 patients were revised for polyethylene wear without loosening (1.2%), which gave a total revision rate of 4.7%. The average postoperative Merle D'Aubigne-Postel scores were 5.7 for pain, 5.5 for range of motion, and 5.4 for function.
机译:我们回顾了173个羟基磷灰石涂层螺旋杯的中期结果。平均随访时间为6。5年(5-9年)。随访率为93%。使用Merle D'Aubigne-Postel临床评分量表和影像学检查对患者进行评估。 2例因反复脱位而进行翻修手术(1.2%),3例因无菌性松动而翻修(1.7%),1例因深部假体感染而进行了翻修手术(0.6%),2例因聚乙烯磨损而翻修而无松动(1.2%),总修订率为4.7%。术后平均Merle D'Aubigne-Postel疼痛评分为5.7,运动范围评分为5.5,功能评分为5.4。