...
首页> 外文期刊>The Journal of heart valve disease >Changes in mitral annular geometry after aortic valve replacement: A three-dimensional transesophageal echocardiographic study
【24h】

Changes in mitral annular geometry after aortic valve replacement: A three-dimensional transesophageal echocardiographic study

机译:主动脉瓣置换后二尖瓣环几何形状的变化:三维经食管超声心动图研究

获取原文
获取原文并翻译 | 示例

摘要

Background and aim of the study: Intraoperative real-time three-dimensional transesophageal echocardiography (RT-3D TEE) was used to examine the geometric changes that occur in the mitral annulus immediately after aortic valve replacement (AVR). Methods: A total of 35 patients undergoing elective surgical AVR under cardiopulmonary bypass was enrolled in the study. Intraoperative RT-3D TEE was used prospectively to acquire volumetric echocardiographic datasets immediately before and after AVR. The 3D echocardiographic data were analyzed offline using TomTec? Mitral Valve Assessment software to assess changes in specific mitral annular geometric parameters. Results: Datasets were successfully acquired and analyzed for all patients. A significant reduction was noted in the mitral annular area (-16.3%, p <0.001), circumference (-8.9%, p <0.001) and the anteroposterior (-6.3%, p = 0.019) and anterolateral- posteromedial (-10.5%, p <0.001) diameters. A greater reduction was noted in the anterior annulus length compared to the posterior annulus length (10.5% versus 6.2%, p <0.05) after AVR. No significant change was seen in the non-planarity angle, coaptation depth, and closure line length. During the period of data acquisition before and after AVR, no significant change was noted in the central venous pressure or left ventricular end-diastolic diameter. Conclusion: The mitral annulus undergoes significant geometric changes immediately after AVR. Notably, a 16.3% reduction was observed in the mitral annular area. The anterior annulus underwent a greater reduction in length compared to the posterior annulus, which suggested the existence of a mechanical compression by the prosthetic valve.
机译:研究的背景和目的:术中实时三维经食管超声心动图(RT-3D TEE)用于检查主动脉瓣置换(AVR)后即刻在二尖瓣环中发生的几何变化。方法:本研究共纳入35例在体外循环下接受择期手术AVR的患者。术前使用RT-3D TEE采集AVR前后的超声心动图数据。使用TomTec?对3D超声心动图数据进行离线分析。二尖瓣评估软件可评估特定二尖瓣环几何参数的变化。结果:所有患者均成功获得数据集并进行了分析。观察到二尖瓣环区域(-16.3%,p <0.001),周长(-8.9%,p <0.001)和前后(-6.3%,p = 0.019)和前外侧后内侧(-10.5%)明显减少,p <0.001)的直径。与AVR后的后瓣环长度相比,前瓣环长度有更大的减少(10.5%对6.2%,p <0.05)。在非平面角,接合深度和闭合线长度上未见明显变化。在AVR前后的数据采集期间,中心静脉压或左心室舒张末期直径无明显变化。结论:AVR后二尖瓣环发生明显的几何变化。值得注意的是,在二尖瓣环区域观察到了16.3%的减少。与后瓣环相比,前瓣环的长度减少得更大,这表明存在人工瓣膜机械压缩。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号