Bonding to cervical sclerotic dentin: effect of acid etching time.

机译:与宫颈硬化性牙本质的粘合:酸蚀时间的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: The aim of this in vitro study was to evaluate the microtensile bond strengths (MTBS) of two total-etch one-bottle adhesive systems to natural cervical lesions with 2 different etching times (15 s vs 30 s). MATERIALS AND METHODS: Thirty-two human canines and premolars with saucer-shaped noncarious cervical defects were cleaned and randomly assigned to 4 groups. The adhesive systems - Single Bond (SB; 3M ESPE) or OptiBond Solo Plus (OP; Kerr) - were applied on cervical dentin after acid etching with the proprietary acid gel (35% or 37.5% phosphoric acid) for 15 s (manufacturer's instruction) or for 30 s. The respective hybrid composite was inserted in three increments and light cured. After 24 h water storage, the specimens were cut perpendicularly with a low-speed diamond saw (Isomet) to obtain slices with a cross section of ca 0.8 mm. After that, the slices were trimmed with a diamond bur to obtain a surface area of 0.7 +/- 0.05 mm2 (n = 12). MTBS was measured in a Bencor device with an Instron machine at a crosshead speed of 0.5 mm/min. The data were subjected to two-way ANOVA and Tukey's LSD post-hoc test (p < 0.05). RESULTS: MTBS are given in MPa (mean +/- SD), where means with the same superscript letter are not statistically different at p < 0.05: OP15 = 30.9 +/- 8.8ab, SB15 = 25.6 +/- 9.6bc, OP30 = 19.0 +/- 4.8c, SB30 = 35.9 +/- 11.0a. When data were pooled for "adhesive system", SB resulted in statistically higher bond strengths than OP (p < 0.043). "Acid etching time" had no significant effect (p < 0.766), but the interaction of the two main factors yielded significant differences (p < 0.0001). Extending etching time to 30 s resulted in a more predictable bond to noncarious cervical sclerotic dentin with SB, but resulted in lower MTBS with OP. CONCLUSION: Composite bonding to cervical sclerotic noncarious dentin may depend on acid demineralization capacity and bonding system. Knowing the etching demineralization rates of the commercially available acid etching seems to be an important factor for selecting the best acid-etching time of cervical sclerotic dentin.
机译:目的:这项体外研究的目的是评估两种全蚀刻单瓶粘合剂系统对自然宫颈病变的两种不同蚀刻时间(15 s vs 30 s)的微拉伸粘合强度(MTBS)。材料与方法:清洗了32具碟形非龋性宫颈缺损的人犬和前磨牙,并将其随机分为4组。在使用专有的酸性凝胶(35%或37.5%磷酸)酸腐蚀15秒钟(制造商的使用说明)后,将胶粘剂体系-Single Bond(SB; 3M ESPE)或OptiBond Solo Plus(OP; Kerr)-涂在宫颈牙本质上)或30秒。将各自的杂化复合物以三个增量插入并进行光固化。储水24小时后,用低速金刚石锯(Isomet)垂直切割样品,以获得横截面约为0.8毫米的切片。之后,将切片用金刚石钻修整,以获得0.7 +/- 0.05 mm2的表面积(n = 12)。在具有Instron机器的Bencor设备中以0.5mm / min的十字头速度测量MTBS。数据经过双向方差分析和Tukey LSD事后检验(p <0.05)。结果:MTBS以MPa(平均值+/- SD)给出,其中具有相同上标字母的均值在p <0.05时无统计学差异:OP15 = 30.9 +/- 8.8ab,SB15 = 25.6 +/- 9.6bc,OP30 = 19.0 +/- 4.8c,SB30 = 35.9 +/- 11.0a。当汇总“胶粘剂体系”的数据时,SB的粘合强度在统计学上高于OP(p <0.043)。 “酸蚀时间”没有显着影响(p <0.766),但是两个主要因素的相互作用产生了显着差异(p <0.0001)。将蚀刻时间延长至30 s可以使SB与非龋齿性颈硬化性牙本质的结合更可预测,但OP可使MTBS降低。结论:复合材料与宫颈硬化性非龋牙本质的结合可能取决于酸脱矿能力和结合系统。知道可商购的酸蚀刻的蚀刻脱矿速率似乎是选择宫颈硬化性牙本质的最佳酸蚀刻时间的重要因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号