首页> 外文期刊>The journal of adhesive dentistry >Influence of smear layer pretreatments on bond strength to dentin.
【24h】

Influence of smear layer pretreatments on bond strength to dentin.

机译:涂片预处理对牙本质粘合强度的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To evaluate the tensile bond strength of two self-etching adhesive systems and one one-bottle system applied on dentin surfaces after different smear layer treatments. MATERIALS AND METHODS: The crowns of 36 extracted third molars were transversally sectioned with a diamond saw to expose dentin. Flat dentin surfaces were abraded wet with 600-grit SiC paper and randomly assigned to 12 groups, according to three adhesive systems--Prime & Bond NT (PB), Clearfil Mega Bond (CMB) and Etch & Prime 3.0 (EP)--and four dentin surface treatments: direct application over smear layer (no treatment), sandblasting with 50 microm Al2O3 for 10 s, etching with 36% phosphoric acid for 15 s, or conditioning with 0.5 M EDTA for 2 min. Composite "crowns" (6.0 mm high) were incrementally built on the bonded surfaces and teeth were stored in distilled water at 37 degrees C. Teeth were vertically, serially sectioned in both x and y directions to obtain bonded specimens of approximately 0.8 mm2 cross-sectional area. Each specimen was tested in tension in a universal testing machine at 0.5 mm/min. RESULTS: Overall microtensile bond strength (MPa) was 40.43 +/- 7.63 for PB, 27.03 +/- 8.40 for CMB, and 14.73 +/- 3.91 for EP. Mean bond strength for PB was significantly higher than self-etching systems. No significant differences were observed among smear layer treatments within the same dentin adhesive. CONCLUSION: Bond strength values were significantly different according to the adhesive system used. Different smear layer treatments prior to bonding did not affect tensile bond strength within the same bonding agent.
机译:目的:评估在不同涂抹层处理后,两种自蚀刻粘合剂体系和一种单瓶体系应用于牙本质表面的拉伸粘合强度。材料与方法:用金刚石锯将36个拔出的第三磨牙的牙冠横向切开以暴露牙本质。根据三种胶粘剂体系-Prime&Bond NT(PB),Clearfil Mega Bond(CMB)和Etch&Prime 3.0(EP)-用600粒度SiC纸将平坦的牙本质表面湿润擦拭并随机分为12组-以及四种牙本质表面处理:直接涂在涂抹层上(无处理),用50微米Al2O3喷砂10秒钟,用36%磷酸蚀刻15秒钟或用0.5 M EDTA进行2分钟处理。将复合“冠”(6.0毫米高)增量地构建在粘合表面上,并将牙齿存储在37摄氏度的蒸馏水中。将牙齿垂直,沿x和y方向连续剖切,以获得约0.8 mm2横截面的粘合样本。截面积。在通用测试仪中以0.5 mm / min的张力测试每个样本。结果:PB的总微拉伸粘合强度(MPa)为40.43 +/- 7.63,CMB为27.03 +/- 8.40,EP为14.73 +/- 3.91。 PB的平均粘结强度显着高于自蚀刻系统。在相同牙本质粘合剂中涂片层处理之间未观察到显着差异。结论:根据所使用的粘合剂体系,粘合强度值存在显着差异。粘结之前的不同涂片层处理不会影响同一粘结剂中的拉伸粘结强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号