...
首页> 外文期刊>The international journal of artificial organs >Stem cell collection using the dideco excel continuous flow blood cell separator: parameters for optimal stem cell collection timing.
【24h】

Stem cell collection using the dideco excel continuous flow blood cell separator: parameters for optimal stem cell collection timing.

机译:使用dideco excel连续流动血细胞分离器进行干细胞收集:最佳干细胞收集时间的参数。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study evaluates stem cell collection procedures performed with the Dideco Excel blood cell separator, with particular attention given to yields and separator collection efficiencies. Patients' blood precounts and yield parameters related to the harvest capacity of the collection system were investigated. Fifty-five collection procedures were analyzed in 32 patients suffering from hematological malignancies and solid tumors and mobilized with chemotherapy plus G-CSF. The median blood volume processed in each procedure was 15.8 liters (12-19.750), with a blood flow rate of 70 ml/min. Patients had the following median blood precount value: NC 7.81x10(9)/L, CD34+ cells 49.08x10(3)/ml. Leukapheresis procedures gave the following yields: NC 14.95x10(9), MNC 10.83x10(9), CD34+ cells 4.37x10(6); yields/kg, NC 0.21x10(9)kg, MNC 0. 15x10(9)/kg CD34+ cells 4.26x10(6)/kg. Procedures show the following collection efficiencies: NC 10.79%, MNC 29.06%, CD34+ 42.33%, PLT 26.5%. The RBC (red blood cell) contamination of the product was (median value) 20.9 ml for each procedure, and for platelets 1.76x10(11) per procedure. The CD34+ cell precounts strongly correlated with the CD34+ yields/kg (r=0.82. p=0.000). Furthermore the NC and MNC precounts correlated with the CD34+ yields/kg but only the MNC precount correlation is notable (r=0.57, p=0.000). The logistic regression analysis shows that CD34+ (p=0.008) but not NC (po=0.14), MNC (p=0.09), or PLT (p=0.53) precounts significantly influenced the collection of a sufficient dose of CD34+ cells for transplantation (> or =2.5x10(6)/kg). Eleven of the thirty-two patients have been transplanted till now, and all had a prompt and lasting trilineage engraftment NC >1x10(9)/L on day 12 (10-17). Our data show that the collection system analyzed in this report is able to collect large amounts of progenitor cells, harvesting >2.5x10(6)/kg CD34+ cells with a single procedure in 68.8% of patients and assuring complete recovery after stem cell transplantation.
机译:这项研究评估了用Dideco Excel血细胞分离器执行的干细胞收集程序,尤其要注意产量和分离器收集效率。研究了患者的血液计数和与采集系统的采集能力相关的产量参数。在32例血液系统恶性肿瘤和实体瘤患者中分析了55种收集方法,并采用化疗加G-CSF进行了动员。在每个过程中处理的中值血液量为15.8升(12-19.750),血液流速为70 ml / min。患者具有以下血液中位数计数值:NC 7.81x10(9)/ L,CD34 +细胞49.08x10(3)/ ml。白细胞分离术产生以下产率:NC 14.95x10(9),MNC 10.83x10(9),CD34 +细胞4.37x10(6);产量/ kg,NC 0.21x10(9)kg,MNC0。15x10(9)/ kg CD34 +细胞4.26x10(6)/ kg。程序显示以下收集效率:NC 10.79%,MNC 29.06%,CD34 + 42.33%,PLT 26.5%。该产品的RBC(红细胞)污染每次操作(中值)为20.9 ml,血小板每次操作为1.76x10(11)。 CD34 +细胞的计数与CD34 +产量/ kg高度相关(r = 0.82。p = 0.000)。此外,NC和MNC预计数与CD34 +产量/ kg相关,但只有MNC预计数相关性显着(r = 0.57,p = 0.000)。逻辑回归分析显示CD34 +(p = 0.008),而非NC(po = 0.14),MNC(p = 0.09)或PLT(p = 0.53)不受计数的影响显着影响了足够剂量的CD34 +细胞的移植( >或= 2.5x10(6)/ kg)。到目前为止,已有32例患者中的11例被移植,所有患者在第12天(10-17)均迅速且持久地接受了三系移植,NC> 1x10(9)/ L。我们的数据表明,本报告中分析的收集系统能够收集大量祖细胞,通过一次手术即可在68.8%的患者中收获> 2.5x10(6)/ kg CD34 +细胞,并确保干细胞移植后完全恢复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号