The objective of the present study was to assess the diagnostic accuracy of the microscopic observation drug susceptibility (MODS) assay for tuberculosis (TB) diagnosis in HIV-infected patients. MEDLINE, EMBASE, LILACS, the Cochrane Central Register of Controlled Trials, African Index Medicus, ResearchGate, SciELO, and the abstracts of the main conferences on infectious diseases and tropical medicine were searched, and other sources investigated. Only studies including HIV-infected patients evaluating MODS for the diagnosis of TB and using culture-based diagnostic tests as a gold standard were analysed. Summary sensitivity and specificity were calculated with a bivariate model. 3259 citations were found, 29 were selected for full-text review and 10 studies including 3075 samples were finally analysed. Overall diagnostic accuracy of MODS for the diagnosis of TB was a sensitivity of 88.3% (95% CI 86.18-90.2%) and specificity 98.2% (95% CI 97.75-98.55%). For multidrug-resistant (MDR)-TB, sensitivity was 89% (95% CI 66.07-97%) and specificity was 100% (95 CI 94.81-100%). For smear-negative pulmonary TB, a sensitivity of 88.2% (95% CI 86.1-89.9%) and specificity of 98.2% (95% CI 96.8-98.9%) were found. Costs varied between USD 0.72 and 7.31 per sample. Mean time to positivity was 8.24 days. MODS was found to have a good accuracy for the diagnosis of TB and MDR-TB in HIV-infected patients with low cost and fast results.
机译:本研究的目的是评估显微镜观察药敏试验(MODS)对HIV感染患者的结核(TB)诊断的诊断准确性。检索了MEDLINE,EMBASE,LILACS,Cochrane对照试验中心登记册,非洲索引医学文献,ResearchGate,SciELO以及传染病和热带医学主要会议的摘要,并调查了其他来源。仅对包括HIV感染患者的评估MODS以诊断结核病并使用基于培养物的诊断测试作为金标准的研究进行了分析。用双变量模型计算总结的敏感性和特异性。共发现3259篇文献,选择29篇全文阅读,最后分析了10项研究,其中包括3075份样品。 MODS对结核病诊断的总体诊断准确性为灵敏度88.3%(95%CI 86.18-90.2%)和特异性98.2%(95%CI 97.75-98.55%)。对于耐多药(MDR)-TB,敏感性为89%(95%CI 66.07-97%),特异性为100%(95 CI 94.81-100%)。对于涂片阴性肺结核,发现敏感性为88.2%(95%CI 86.1-89.9%),特异性为98.2%(95%CI 96.8-98.9%)。每个样品的成本在0.72美元至7.31美元之间。平均阳性时间为8.24天。发现MODS对HIV感染患者的结核病和耐多药结核病的诊断具有良好的准确性,且成本低,结果快。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号