首页> 外文期刊>The European physical journal. Applied physics >Experiments of draining and filling processes in a collapsible tube at high external pressure
【24h】

Experiments of draining and filling processes in a collapsible tube at high external pressure

机译:高外部压力下可折叠管中的排水和填充过程的实验

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The venous circulation in the lower limb is mainly controlled by the muscular action of the calf. To study the mechanisms governing the venous draining and filling process in such a situation, an experimental setup, composed by a collapsible tube under external pressure, has been built. A valve preventing back flows is inserted at the bottom of the tube and allows to model two different configurations: physiological when the fluid flow is uni-directional and pathological when the fluid flows in both directions. Pressure and flow rate measurements are carried out at the inlet and outlet of the tube and an original optical device with three cameras is proposed to measure the instantaneous cross-sectional area. The experimental results (draining and filling with physiological or pathological valves) are confronted to a simple one-dimensional numerical model which completes the physical interpretation. One major observation is that the muscular contraction induces a fast emptying phase followed by a slow one controlled by viscous effects, and that a defect of the valve decreases, as expected, the ejected volume.
机译:下肢的静脉循环主要由小腿的肌肉动作控制。为了研究在这种情况下控制静脉排液和充盈过程的机制,已建立了由外部压力下的可折叠管组成的实验装置。防止回流的阀插入管的底部,并允许对两种不同的构造进行建模:当流体单向流动时为生理状态;当流体双向流动时为病理状态。在管子的入口和出口进行压力和流速测量,并建议使用带有三个摄像头的原始光学设备来测量瞬时横截面积。实验结果(排泄并填充生理或病理阀门)遇到了一个简单的一维数值模型,该模型完成了物理解释。一个主要的观察结果是,肌肉收缩引起一个快速的排空阶段,随后是一个由粘性作用控制的缓慢的排空阶段,并且瓣膜的缺陷如预期的那样减少了排出的体积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号