首页> 外文期刊>The European physical journal, E. Soft matter >Contribution to the benchmark for ternary mixtures: Measurement of the Soret and thermodiffusion coefficients of tetralin plus isobutylbenzene plus n-dodecane at a composition of (0.8/0.1/0.1) mass fractions by two-color optical beam deflection
【24h】

Contribution to the benchmark for ternary mixtures: Measurement of the Soret and thermodiffusion coefficients of tetralin plus isobutylbenzene plus n-dodecane at a composition of (0.8/0.1/0.1) mass fractions by two-color optical beam deflection

机译:对三元混合物基准的贡献:通过两种颜色的光束偏转,测量质量分数为(0.8 / 0.1 / 0.1)的四氢化萘,异丁苯和正十二烷的Soret和热扩散系数

获取原文
获取原文并翻译 | 示例
           

摘要

Within the framework of an international benchmark test we have performed measurements of the Soret and thermodiffusion coefficients of the organic ternary mixture (0.8/0.1/0.1 mass fraction) of 1,2,3,4-tetrahydronaphthaline (THN), isobutylbenzene (IBB) and n -dodecane (n C12) at 298.15K by means of a two-color optical beam deflection technique (OBD). The data evaluation procedure is based on a least squares fitting routine for an approximate analytical solution for the Soret cell problem. The condition number of the contrast factor matrix and standard error propagation are used for an error estimation for the measured Soret and thermodiffusion coefficients. The Soret coefficients obtained are S'(T)(THN) = (1.20 +/- 0.09)x10(-3) K-1, S'(T)(IBB) = (- 0.34 +/- 0.14)x10(-3) K-1, and S'(T)(nC12) = (- 0.86 +/- 0.06)x10(-3) K-1 and the corresponding thermodiffusion coefficients are D'(T)(THN) = (0.72 +/- 0.26)x10(-12) m(2)(s K)(-1), D'(T)(IBB) = (- 0.22 +/- 0.42)x10(-12) m(2)(s K)(-1), and D'(T)(nC12) = (- 0.50 +/- 0.16)x10(-12) m(2)(s K)(-1). These results will be used as ground-based reference data for the DCMIX project, where thermodiffusion experiments of ternary mixtures are measured in a microgravity environment aboard the International Space Station (ISS).
机译:在国际基准测试的框架内,我们对1,2,3,4-四氢萘(THN),异丁苯(IBB)的有机三元混合物(质量分数为0.8 / 0.1 / 0.1)的Soret和热扩散系数进行了测量。通过双色光束偏转技术(OBD)在298.15K时生成正十二烷(n C12)。数据评估程序基于最小二乘拟合例程,用于Soret单元问题的近似解析解。对比因子矩阵的条件编号和标准误差传播用于对测得的Soret和热扩散系数进行误差估计。获得的Soret系数为S'(T)(THN)=(1.20 +/- 0.09)x10(-3)K-1,S'(T)(IBB)=(-0.34 +/- 0.14)x10(- 3)K-1,并且S'(T)(nC12)=(-0.86 +/- 0.06)x10(-3)K-1,相应的热扩散系数为D'(T)(THN)=(0.72 + /-0.26)x10(-12)m(2)(s K)(-1),D'(T)(IBB)=(-0.22 +/- 0.42)x10(-12)m(2)(s K)(-1)和D'(T)(nC12)=(-0.50 +/- 0.16)x10(-12)m(2)(s K)(-1)。这些结果将用作DCMIX项目的地面参考数据,该项目在国际空间站(ISS)的微重力环境中测量三元混合物的热扩散实验。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号