A novel three-dimensional (3-D) tomography software has been developed for spherical tokamak (ST) plasmas with thin central coils. It enables us to measure whole 3-D annular profiles of ST plasma emissivity (line spectrum etc.) using limited number of detectors located on a sphere outside of its separatrix. The numbers and positions of detectors have been optimized for STs that contain low-n toroidal modes from n = 1 to 5. Mathematical method allowing for the removal of the thin central coil from the region of reconstruction and to reconstruct STs with single and double axes are also discussed. The shadow effect of center coil region was found to limit the reconstruction accuracy, indicating that the low-aspect ratio torus (ST) is essential to this new 3-D tomography diagnostics.
机译:已经开发了一种新颖的三维(3-D)层析成像软件,用于具有薄中央线圈的球形托卡马克(ST)等离子体。它使我们能够使用位于分离器外部的球体上的有限数量的检测器来测量ST等离子体发射率的整个3-D环形轮廓(线谱等)。检测器的数量和位置已针对包含从n = 1到5的低n环形模式的ST进行了优化。数学方法允许从重建区域去除薄的中心线圈,并重建单轴和双轴ST也进行了讨论。发现中心线圈区域的阴影效应限制了重建精度,这表明低纵横比的圆环面(ST)对这种新型3D层析成像诊断至关重要。