Assessment of effort on cognitive testing has become a suggested standard in both forensic and clinical neuropsychological assessment. Both stand-alone and empirically derived embedded measures have been developed, however guidelines for combining several measures are not always available. This study used logistic regression analysis to derive a multivariable composite to detect suboptimal effort using scores extracted from commonly administered neuropsychological tests. A model predicting suboptimal effort, as defined by performance on the Medical Symptom Validity Test, was created with 124 participants using variables from the California Verbal Learning test 2nd edition, Rey Complex Figure Test and the Wechsler Memory Scale 3rd edition. The model reliably predicted suboptimal effort (chi(2 )= 44.37, p < .001) with excellent discrimination (AUC = .84).
机译:评估认知测验的努力已成为法医和临床神经心理学评估的建议标准。已经开发了独立的和根据经验得出的嵌入式测度,但是结合几种测度的指南并不总是可用。这项研究使用逻辑回归分析得出了一个多变量组合,使用从通常进行的神经心理学测试中提取的分数来检测次优努力。由124名参与者使用来自加州言语学习测验第2版,雷伊复杂图形测验和Wechsler记忆量表第3版的变量,由124名参与者创建了一个预测效果欠佳的模型,该模型由医学症状有效性测试中的表现定义。该模型以出色的判别力(AUC = .84)可靠地预测了次优工作量(chi(2)= 44.37,p <.001)。