Mammographic density estimation: comparison among BI-RADS categories, a semi-automated software and a fully automated one.

机译:乳腺密度估计:BI-RADS类别,半自动化软件和全自动软件之间的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Although breast density is considered a strong predictor of breast cancer risk, its quantitative assessment is difficult. The aim of this study is to demonstrate that breast density assessment with a fully automated software is feasible and correlates with the semi-automated evaluation and the quantitative BI-RADS standards. A data set of 160 mammograms was evaluated by three blinded radiologists. Intra-observer (reader 1: k=0.71; reader 2: k=0.76; reader 3: k=0.62) and inter-observer (reader 1 vs reader 2: k=0.72; reader 2 vs reader 3: k=0.80; reader 3 vs reader 1: k=0.72) variability for the semi-automated software were good on a four-grade scale (D1/D2/D3/D4) and correlated with BI-RADS evaluation made by other two blinded radiologists (r=0.65, p<0.01). Inter-observer (reader 1 vs reader 2: k=0.85; reader 2 vs reader 3: k=0.91; reader 3 vs reader 1: k=0.85) variability for the semi-automated software was very good on a two-grade scale (D1-D2/D3-D4). The use of the fully automated software eliminated intra- and inter-observer differences, correlated with BI-RADS categories (r=0.62, p<0.01) and can replace the semi-automated one (Bland-Altman statistics). Our study demonstrates that automated estimation of breast density is feasible and eliminates subjectivity. Furthermore both the semi-automated and the fully automated density estimation are more accurate than BI-RADS quantitative evaluation and could also be used in the daily clinical practice.
机译:尽管乳房密度被认为是乳腺癌风险的有力预测指标,但其定量评估却很困难。这项研究的目的是证明使用全自动软件进行乳房密度评估是可行的,并且与半自动化评估和定量BI-RADS标准相关。由三位不知情的放射线医师评估了160幅乳腺X线照片的数据集。观察者内部(阅读器1:k = 0.71;阅读器2:k = 0.76;阅读器3:k = 0.62)和观察者之间(阅读器1与阅读器2:k = 0.72;阅读器2与阅读器3:k = 0.80;阅读器3与阅读器1:k = 0.72),半自动化软件的可变性在四级刻度(D1 / D2 / D3 / D4)上很好,并且与其他两位盲放射科医生进行的BI-RADS评估相关(r = 0.65,p <0.01)。观察者之间(阅读器1与阅读器2:k = 0.85;阅读器2与阅读器3:k = 0.91;阅读器3与阅读器1:k = 0.85),半自动化软件的可变性在两个等级上都非常好(D1-D2 / D3-D4)。全自动软件的使用消除了观察者之间和观察者之间的差异,这些差异与BI-RADS类别相关(r = 0.62,p <0.01),并且可以替代半自动化软件(Bland-Altman统计数据)。我们的研究表明,自动估算乳房密度是可行的,并且消除了主观性。此外,半自动和全自动密度估计均比BI-RADS定量评估更准确,也可用于日常临床实践中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号