...
首页> 外文期刊>The Bovine Practitioner >Effects of ear-notch sample handling on reliability of antigen-capture enzyme-linked immunosorbent assay testing for bovine viral diarrhea virus
【24h】

Effects of ear-notch sample handling on reliability of antigen-capture enzyme-linked immunosorbent assay testing for bovine viral diarrhea virus

机译:耳缺口样品处理对牛病毒性腹泻病毒抗原捕获酶联免疫吸附测定法可靠性的影响

获取原文
获取原文并翻译 | 示例

摘要

Antigen-capture enzyme-linked immunosorbent assay (ACE) testing of skin samples obtained by ear-notching is commonly used to detect animals persistently infected (PI) with bovine viral diarrhea virus (BVDV). At times practitioners may not have access to phosphate buffered saline (PBS) solution for specimen storage as suggested by the ACE kit manufacturer. The first objective of this study was to observe the effects of storing ear-notch samples in varying amounts of PBS on ACE results. The second objective was to observe the effects of delayed time before the ear-notch sample was placed in PBS on the ACE results. Using virus isolation and immunohistochemistry, nine PI-positive and eight PI-negative calves were identified to obtain ear notch biopsies for the study. The amount of PBS used to store both positive and negative ear-notch samples was varied (1, 2, 4, 6, 8 and 10 mL) in the first trial. In the second trial, the addition of PBS to both positive and negative samples was delayed post-collection; phosphate buffered saline was added to ear-notch samples at 0, 1, 2, 4, 8, 12 and 24 hours post-collection. Following sampling and application of treatments, all samples were tested in duplicate for BVDV antigen following the guidelines of the ACE kit manufacturer. Although the S/P ratios were different among treatment groups in both studies (P<0.05), neither varying the amount of PBS added to the sample vial nor delaying the addition of PBS to the sample affected the outcome when testing positive or negative samples.
机译:通过耳缺口获得的皮肤样品的抗原捕获酶联免疫吸附测定(ACE)测试通常用于检测持续感染(PI)牛病毒性腹泻病毒(BVDV)的动物。有时,如ACE试剂盒制造商所建议,从业人员可能无法使用磷酸盐缓冲液(PBS)溶液进行标本存储。这项研究的第一个目的是观察以不同量的PBS储存耳缺口样品对ACE结果的影响。第二个目的是观察将耳凹样品放入PBS中之前延迟时间对ACE结果的影响。使用病毒分离和免疫组织化学,鉴定出九只PI阳性小牛和八只PI阴性小牛,以获得用于研究的耳口活检。在第一个试验中,用于存储阳性和阴性耳凹样品的PBS量有所不同(1、2、4、6、8和10 mL)。在第二项试验中,正样本和负样本中都添加了PBS,采集后被延迟了。在采集后的0、1、2、4、8、12和24小时,将磷酸缓冲盐溶液添加到耳凹样品中。取样并进行处理后,按照ACE试剂盒制造商的指导,一式两份测试所有样品的BVDV抗原。尽管在两个研究中治疗组之间的S / P比率均不同(P <0.05),但在测试阳性或阴性样品时,既不改变添加到样品瓶中的PBS的量,也不延迟延迟添加到样品中的PBS会影响结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号