首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >In situ detection of Bacillus anthvacis spores using fully submersible, self-exciting, self-sensing PMN-PT/Sn piezoelectric microcantilevers
【24h】

In situ detection of Bacillus anthvacis spores using fully submersible, self-exciting, self-sensing PMN-PT/Sn piezoelectric microcantilevers

机译:使用完全浸没,自激,自感的PMN-PT / Sn压电微悬臂梁原位检测炭疽芽孢杆菌孢子

获取原文
获取原文并翻译 | 示例

摘要

In this study, we have demonstrated in situ, all-electrical detection of Bacillus anthracis (BA) spores using lead magnesium niobate-lead titanate/tin (PMN-PT/Sn) piezoelectric microcantilever sensors (PEMS) fabricated from PMN-PT freestanding films and electrically insulated with methyltrimethoxysilane (MTMS) coatings on the tin surface. Antibody specific to BA spore surface antigen was immobilized on the platinum electrode of the PMN-PT layer. In phosphate-buffered saline (PBS) solution, the PMN-PT/Sn PEMS exhibited quality (0 values ranging from 50 to 75. The detection was carried out in a closed-loop flow cell with a liquid volume of 0.8 ml and a flow rate of 1 ml min~(-1). It was shown that one sensor, "PEMS-A" (500 urn long, 800 um wide, with a 22 mu m thick PMN-PT layer, a 20 urn thick tin layer and a 1 + 0.5 x 10~(-12)gHz~(-1) mass detection sensitivity) exhibited resonance frequency shifts of 2100 + 200, 1100 + 100 and 700 + 100 Hz at concentrations of 20 000, 2000, and 200 spores ml~(-1) or 16 000, 1600, and 160 total spores, respectively. Additionally, "PEMS-B" (350 um long, 800 um wide, with an 8 mu m thick PMN-PT layer, a 6 mu m thick tin layer and a 2 + 1 x 10~(-13) g Hz~(-1) mass detection sensitivity) exhibited resonance frequency shifts of 2400 + 200, 1500 + 200, 500 ± 150 and 200 ± 100 Hz at concentrations of 20 000, 2000, 100, and 45 spores ml"1 or 16 000, 1600, 80, and 36 total spores, respectively.
机译:在这项研究中,我们已经证明了使用由PMN-PT独立膜制成的铌酸铅镁-钛酸铅/锡(PMN-PT / Sn)压电微悬臂梁传感器(PEMS)原位全电检测炭疽芽胞杆菌(BA)孢子并在锡表面上用甲基三甲氧基硅烷(MTMS)涂层进行电绝缘。对BA孢子表面抗原具有特异性的抗体被固定在PMN-PT层的铂电极上。在磷酸盐缓冲盐水(PBS)溶液中,PMN-PT / Sn PEMS显示出质量(0值介于50到75之间。检测是在闭环流通池中进行的,该流通池的液体体积为0.8 ml,速率为1 ml min〜(-1)。结果表明,一个传感器“ PEMS-A”(长500 n,宽800 um,具有22微米厚的PMN-PT层,20 thick厚的锡层和1 + 0.5 x 10〜(-12)gHz〜(-1)质量检测灵敏度)在20000、2000和200孢子ml的浓度下显示2100 + 200、1100 + 100和700 + 100 Hz的共振频率偏移分别为〜(-1)或16 000、1600和160个总孢子。另外,“ PEMS-B”(长350 um,宽800 um,具有8微米厚的PMN-PT层,6微米厚锡层和2 + 1 x 10〜(-13)g Hz〜(-1)质量检测灵敏度)在浓度为20时表现出2400 + 200、1500 + 200、500±150和200±100 Hz的共振频率偏移000、2000、100和45个孢子ml“ 1或16 000、1600、80和36个总孢子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号