首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Real-time monitoring of stain formation and removal on calcium hydroxyapatite surfaces using quartz crystal sensor technology
【24h】

Real-time monitoring of stain formation and removal on calcium hydroxyapatite surfaces using quartz crystal sensor technology

机译:使用石英晶体传感器技术实时监测羟基磷灰石钙表面上的污斑形成和去除情况

获取原文
获取原文并翻译 | 示例
       

摘要

Stain formation,stain inhibition and stain removal may be monitored in real-time using a novel method employing a quartz crystal resonance sensor (QCR),based upon quartz crystal microbalance (QCM) technologies.Crystalline hydroxyapatite (HA) surfaces were prepared on phosphate-terminated,polymer-modified gold surfaces of quartz crystal transducers.The resulting sensors were placed in a specially constructed flow cell,and the interaction of adsorbates from the tea stain solution monitored as a function of time.The ability of sodium tripolyphosphate (STP) to remove extrinsic stain and also to inhibit its formation was examined.The adsorption of material from the staining solution passes over the sensor was clearly observable,and once bound,the crystal based real-time data suggest that tea adsorbates were not removed in the absence of an active under conditions of continuous flow.STP was shown to rapidly remove existing stain, and exhibited a clear inhibitory action on stain formation irrespective of whether the HA had been previously exposed to tea chromogens.The continuous data generated by the QCR technique were in good agreement with the results obtained using a discontinuous spectrophotomeric method.The presently described quartz crystal model for extrinsic dental stain should provide a valuable tool to aid understanding of the interactions of staining agents with a crystalline HA surface as a model tooth surface,and to evaluate the efficacy and mode of action of STP and putative stain removal agents.
机译:可以使用一种基于石英晶体微天平(QCM)技术的,采用石英晶体共振传感器(QCR)的新方法来实时监测污渍的形成,抑制污渍和去除污渍。在磷酸盐处理的磷酸钙表面制备晶体羟基磷灰石(HA)表面。终止的,经聚合物修饰的石英晶体传感器的金表面。将得到的传感器放置在特制的流通池中,并监测茶渍溶液中吸附物的相互作用随时间的变化。三聚磷酸钠(STP)的能力可以清楚地观察到从染色液中流过传感器的物质的吸附,并且一旦结合,基于晶体的实时数据表明在不存在茶色素的情况下不能去除茶色素。 STP被证明可以快速去除现有的污渍,并且对污渍的形成有明显的抑制作用。 QCR技术产生的连续数据与使用不连续分光光度法获得的结果非常吻合。目前描述的用于外源性牙渍的石英晶体模型应提供有价值的工具有助于了解染色剂与结晶HA表面(作为模型牙齿表面)之间的相互作用,并评估STP和推定的去污剂的功效和作用方式。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号