PVC film containing various activants was coated on one electrode of a thickness-shear mode piezoelectric quartz crystal (PQC) to fabricate a trimethoprim (TMP) ion-selective piezoelectric sensor for the determination of TMP. The method is based on the selective adsorption of TMP ion on the modified film and the sensitive mass response of the PQC. The method was found to be sensitive, rapid and easy to handle with no need for previous sample treatment. The logarithm of frequency shift of PQC was found to bear a linear relationship to the logarithm of the concentration of TMP over the range 2 x 10(-8)-2 x 10(-3) M with a detection Limit of 2 x 10(-8) M at pH 4.0. Recoveries were from 99-102.9%. Two activants, TMP phosphotungstate and TMP silicotungstate, were synthesized and investigated. Influencing factors were examined in detail and optimized. The results for real samples obtained by the proposed method agreed with those obtained by a conventional method. [References: 28]
机译:将包含各种活化剂的PVC膜涂覆在厚度剪切模式压电石英晶体(PQC)的一个电极上,以制造甲氧苄啶(TMP)离子选择性压电传感器,用于测定TMP。该方法基于TMP离子在改性膜上的选择性吸附和PQC的敏感质量响应。发现该方法灵敏,快速且易于操作,无需先前的样品处理。发现PQC频移的对数与TMP浓度在2 x 10(-8)-2 x 10(-3)M范围内的对数呈线性关系,检出限为2 x 10( -8)M在pH 4.0下。回收率为99-102.9%。合成并研究了两种活化剂,TMP磷钨酸盐和TMP硅钨酸盐。影响因素进行了详细检查和优化。通过提议的方法获得的真实样品的结果与通过常规方法获得的结果一致。 [参考:28]