首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Sensitive determination of heroin based on electrogenerated chemiluminescence of tris(2,2 '-bipyridyl)ruthenium(II) immobilized in zeolite Y modified carbon paste electrode
【24h】

Sensitive determination of heroin based on electrogenerated chemiluminescence of tris(2,2 '-bipyridyl)ruthenium(II) immobilized in zeolite Y modified carbon paste electrode

机译:基于固定在沸石Y修饰碳糊电极上的三(2,2'-联吡啶基)钌(II)的化学发光法测定海洛因

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A novel method for rapid, inexpensive, sensitive and selective determination of heroin was proposed by flow injection electrogenerated chemiluminescence (ECL). Zeolite Y sieves were used for the preparation of a ECL sensor by immobilizing tris(2,29-bipyridyl) ruthenium(II) (Ru(bpy) (2+)(3)) in their supercages, which was achieved through the ion exchange properties of the sieves. The electrochemical and ECL behaviors of Ru(bpy)(3)(2+) immobilized in zeolite Y modified carbon paste electrode was investigated. The immobilized Ru(bpy)(3)(2+) displayed a pair of surface-controlled redox peaks with an electron transfer rate constant of 1.2 +/- 0.1 s(-1) in 0.1 mol dm(-3) pH 6.3 phosphate buffer. The modified electrode showed an electrocatalytic response to the oxidation of heroin, producing a sensitized ECL signal. The ECL sensor showed a linear response to flow injection of heroin in the range of 2.0-80 mu mol dm(-3) with a detection limit of 1.1 mu mol dm(-3). This method for heroin determination possessed good sensitivity and reproducibility with a coefficient of variation of 1.99% (n = 15) at 50.0 mu mol dm(-3). The ECL sensor showed good selectivity and long-term stability. Its surface could be renewed quickly and reproducibly by a simple polish step.
机译:通过流动注射电化学发光(ECL)提出了一种快速,廉价,灵敏和选择性测定海洛因的新方法。 Y型沸石筛通过将三(2,29-联吡啶基)钌(II)(Ru(bpy)(2 +)(3))固定在它们的超笼中而用于制备ECL传感器,这是通过离子交换实现的筛子的性质。研究了固定在沸石Y修饰碳糊电极上的Ru(bpy)(3)(2+)的电化学和ECL行为。固定化的Ru(bpy)(3)(2+)在0.1 mol dm(-3)pH 6.3磷酸盐中显示出一对表面控制的氧化还原峰,其电子传递速率常数为1.2 +/- 0.1 s(-1)缓冲。修饰的电极对海洛因的氧化表现出电催化反应,产生敏化的ECL信号。 ECL传感器对海洛因的流动注射显示线性响应,范围为2.0-80μmoldm(-3),检测极限为1.1μmoldm(-3)。该海洛因测定方法具有良好的灵敏度和重现性,在50.0μmol dm(-3)时的变异系数为1.99%(n = 15)。 ECL传感器显示出良好的选择性和长期稳定性。通过简单的抛光步骤可以快速,可重复地更新其表面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号