首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Cathodic stripping voltammetric determination of ultratrace gold(III) at a bulk modified epoxy-graphite tube composite electrode in flow systems
【24h】

Cathodic stripping voltammetric determination of ultratrace gold(III) at a bulk modified epoxy-graphite tube composite electrode in flow systems

机译:流动系统中本体改性环氧-石墨管复合电极的阴极溶出伏安法测定痕量金(III)

获取原文
获取原文并翻译 | 示例
           

摘要

An epoxy-impregnated graphite tube composite electrode bulk; modified with 2-mercaptobenzoxazole was fabricated and employed for the determination of gold. A differential-pulse cathodic stripping procedure in conjunction with either continuous flow or flow injection was developed. Both open and closed circuit accumulation of Au(III) were investigated. The addition of Rhodamine 6G to the accumulation medium enhanced the sensitivity. Factors influencing the analysis were optimized. For continuous flow, precisions were 6.33% [relative standard deviation, la = 6, 5.00 x 10(-8) M Au(III), accumulation 10 min, open circuit] and 7.06% [n = 6, 1.00 x 10(-9) M Au(III), accumulation 10 min, closed circuit]. The detection limits (S/N = 3) were 6.7 x 10-9 and 1.9 x 10(-10) M Au(III) for Open and closed circuit accumulations, respectively, with 10 min accumulation. For flow injection under similar conditions, the detection limits were 3.1 x 10(-7) M Au(III) (open circuit, injection volume 500 mu l, 30.5 ng injected) and 2.9 x 10-9 hi (closed circuit, injection volume 500 mu l, 0.29 ng injected). Selected metal ions and other inorganic and organic substances were examined for interferences. The developed method was applied to a certified water sample (US EPA WP 386), a sea-water sample and a pin-connector sample. [References: 29]
机译:环氧浸渍石墨管复合电极块;制备了用2-巯基苯并恶唑改性的金,并用于测定金。开发了与连续流动或流动注射相结合的差分脉冲阴极剥离方法。研究了Au(III)的开路和闭路累积。将罗丹明6G添加到累积培养基中可提高灵敏度。优化了影响分析的因素。对于连续流动,精度为6.33%[相对标准偏差,la = 6,5.00 x 10(-8)M Au(III),累积10分钟,开路]和7.06%[n = 6,1.00 x 10(- 9)M Au(III),累积10分钟,闭路]。开路和闭路累积的检测极限(S / N = 3)分别为6.7 x 10-9和1.9 x 10(-10)M Au(III),累积10分钟。对于在类似条件下的进样,检测限为3.1 x 10(-7)M Au(III)(开路,进样量500μl,注入30.5 ng)和2.9 x 10-9 hi(闭路,进样量) 500微升,注入0.29 ng)。检查了选定的金属离子以及其他无机和有机物质的干扰。所开发的方法适用于经认证的水样本(US EPA WP 386),海水样本和引脚连接器样本。 [参考:29]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号