...
首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Simultaneous determination of 11 polycyclic aromatic hydrocarbons (PAHs) by second-derivative synchronous spectrofluorimetry considering the possibility of quenching by some PAHs in the mixture
【24h】

Simultaneous determination of 11 polycyclic aromatic hydrocarbons (PAHs) by second-derivative synchronous spectrofluorimetry considering the possibility of quenching by some PAHs in the mixture

机译:考虑到混合物中某些PAH可能淬灭的可能性,通过二阶导数同步光谱荧光法同时测定11种多环芳烃(PAH)

获取原文
获取原文并翻译 | 示例

摘要

A method capable of determining 11 PAHs (acenaphthene, anthracene, benz[a]anthracene, benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, chrysene, phenanthrene, fluoranthene, indeno[1,2,3-cd]pyrene and perylene) in a mixture of 18 by second-derivative synchronous spectrofluorimetry in the constant wavelength mode was developed. It has not been possible to determine the following PAHs in the mixture. dibenz[a,h]anthracene, fluorene, indene, naphthalene, pyrene, triphenylene and 1,12-benzoperylene. The possibility of selective quenching of some molecules by others in the mixture was considered and it was found that the fluorescent signal of fluorene is quenched by indeno[1,2,3-cd]pyrene. Other papers related to complex mixtures have not taken this possibility into account; on the other hand, the identification and quantification of PAHs in such a complex mixture (18 compounds) has never been attempted before. The approach studied allows the sensitive, rapid, easy and inexpensive identification and quantification of 11 PAHs in a solution of hexane. The detection limits are between 0.01 and 0.70 ng ml(-1) in most cases (except for indeno[1,2,3-cd]pyrene with a detection limit of 4.95 ng ml(-1)) and a short analysis time (four PAHs were determined in one interval alone, Delta lambda = 95 nm), the total identification and quantification of the PAHs taking only 10 min. [References: 33]
机译:一种能够测定11种PAHs的方法(ac,蒽,苯并[a]蒽,苯并[a] py,苯并[b]荧蒽,苯并[k]荧蒽、,、菲,荧蒽,茚并[1,2,3-通过二阶导数同步光谱荧光法在恒定波长模式下开发了18的混合物中的cd] and和per。不可能确定混合物中的以下PAH。二苯并[a,h]蒽,芴,茚,萘,pyr,联苯和1,12-苯并per。考虑了混合物中某些分子被其他分子选择性淬灭的可能性,发现芴的荧光信号被茚并[1,2,3-cd] py淬灭。其他与复杂混合物有关的论文没有考虑到这种可能性。另一方面,从未尝试过在这种复杂混合物(18种化合物)中鉴定和定量PAHs。所研究的方法可以对己烷溶液中的11种PAH进行灵敏,快速,简便且廉价的鉴定和定量。在大多数情况下,检出限在0.01至0.70 ng ml(-1)之间(茚并[1,2,3-cd] py除外,检出限为4.95 ng ml(-1))且分析时间短(仅在一个时间间隔内就测定了四个PAH(Deltaλ= 95 nm),对PAH的总鉴定和定量仅需10分钟。 [参考:33]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号