首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >The analysis of beta-agonists by packed-column supercritical fluid chromatography with ultra-violet and atmospheric pressure chemical ionisation mass spectrometric detection
【24h】

The analysis of beta-agonists by packed-column supercritical fluid chromatography with ultra-violet and atmospheric pressure chemical ionisation mass spectrometric detection

机译:填充柱超临界流体色谱-紫外和大气压化学电离质谱检测对β-激动剂的分析

获取原文
获取原文并翻译 | 示例
           

摘要

Packed-column supercritical fluid chromatography (pSFC) using ultra-violet (UV) and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS) provides a versatile method for the identification and quantification of beta-agonists. We have achieved good separation of clenbuterol, salbutamol, terbutaline and fenoterol with good resolution and reasonable retention times using a high concentration of methanol modifier in the supercritical CO2, together with small amounts of both acidic (trifluoroacetic acid, TFAA) and basic (triethylamine, TEA, or diethylamine, DEA) additives. APCI-MS gave unambiguous identification of the 4 analytes, and increasing cone voltage provided informative fragmentation patterns. The pSFC-MS technique was shown to be linear (R-2 greater than or equal to 0,996) over the concentration range 1-50 mu g ml(-1). Single ion monitoring (SIM) gave detection limits (on-column) of 2.5 ng (clenbuterol), 0.83 ng (terbutaline), 7.6 ng (salbutamol) and 2.7 ng (fenoterol). The pSFC-MS system was shown to be reproducible within a day between days, and between restrictors. Analysis of milk samples 'spiked' with beta-agonists showed that th; matrix caused no interference, with detection limits of approximately 500 mu g l(-1) of beta-agonists, More dilute solutions could be analysed by pre-concentration before: the SFC stage. [References: 17]
机译:使用紫外线(UV)和大气压化学电离(APCI)质谱(MS)的填充柱超临界流体色谱(pSFC)提供了鉴定和定量β-激动剂的通用方法。在超临界CO2中使用高浓度的甲醇改性剂,同时使用少量的酸性(三氟乙酸,TFAA)和碱性(三乙胺, TEA或二乙胺(DEA)添加剂。 APCI-MS明确鉴定了4种分析物,增加的锥孔电压提供了有益的碎片模式。 pSFC-MS技术显示在1-50μgml(-1)的浓度范围内是线性的(R-2大于或等于0,996)。单离子监测(SIM)的检测限(柱上)为2.5 ng(瘦肉精),0.83 ng(特布他林),7.6 ng(沙丁胺醇)和2.7 ng(非诺特罗)。 pSFC-MS系统显示出可在几天之间和限制器之间的一天之内重现。用β-激动剂“加标”牛奶样品的分析表明:基质不会引起干扰,检测限约为500μg l(-1)的β-激动剂,在SFC阶段之前,可通过预浓缩分析更多稀溶液。 [参考:17]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号