...
首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts
【24h】

Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts

机译:使用ATR测量溶剂提取物干膜的化学计量方法测定血清中的脂质参数

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane-isopropanol and ethyl acetate-ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample extracts could be related quantitatively to variations in the concentrations of the target analytes. Then, ATR spectra of the dried sample extracts were obtained and direct measurement of the spectra were carried out and modelled using partial least squares (PLS) and reference concentrations. PLS models obtained from the extracts of the two mixtures were compared with those obtained from direct measurement of sera samples. The prediction errors obtained using the proposed approach were considerably (between 27 and 72%) better than those obtained by the direct measurements of sera. For triglycerides and cholesterol relative errors below 9% and 12% respectively were obtained with this method, which are comparable to the tolerance for the errors of the control analysis established at the hospital. For HDL and LDL, the errors found were between 18 and 20%. The incorporation of a preprocessing extraction step, involves time and solvent consumption. However, the results obtained provide evidence that the proposed method provides, in a few minutes and using simple instrumentation and with minimum cost, important information about the lipidic profile of patients sera at a good screening confidence level.
机译:血清样品干燥有机提取物的衰减全反射(ATR)红外光谱已被评估为测定甘油三酸酯,胆固醇,高密度脂蛋白(HDL)和低密度脂蛋白(LDL)的快速方法。根据绿色参数仔细选择溶剂后,使用己烷-异丙醇和乙酸乙酯-乙醇混合物提取血清样品。为了研究所提出的方法是否适合定量血清样品中的脂质,进行了显微镜研究和与标准光谱的比较。这些初步研究的结果证实,样品提取物的红外光谱变化可能与目标分析物浓度的变化定量相关。然后,获得干燥样品提取物的ATR光谱,并使用偏最小二乘(PLS)和参考浓度对光谱进行直接测量和建模。比较了从两种混合物的提取物中获得的PLS模型与直接测量血清样品获得的PLS模型。使用建议的方法获得的预测误差比直接测量血清获得的预测误差要好得多(介于27%和72%之间)。对于甘油三酸酯和胆固醇,使用该方法分别获得的相对误差分别低于9%和12%,这与医院建立的对照分析的误差容忍度相当。对于HDL和LDL,发现的错误在18%到20%之间。预处理萃取步骤的合并涉及时间和溶剂消耗。然而,获得的结果提供了证据,表明所提出的方法在几分钟内并且使用简单的仪器并且以最低的成本提供了关于患者血清脂质分布的重要信息,并且具有良好的筛选置信度。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号