A study was conducted to evaluate the homogeneity of the distribution of metals and metalloids deposited on glass fiber filters collected using a high-volume sampler equipped with a PM-10 sampling head. The airborne particulate matter (APM)-loaded glass fiber filters (with an active surface of about 500 cm(2)) were weighed and then each filter was cut in five small discs of 6.5 cm of diameter. Each disk was mineralized by acid-assisted microwave (MW) digestion using a mixture of nitric, perchloric and hydrofluoric acids. Analysis was performed by axial view inductively coupled plasma optical emission spectrometry (ICP OES) and the elements considered were: Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Ti and V. The validation of the procedure was performed by the analysis of the standard reference material NIST 1648, urban particulate matter. As a way of comparing the possible variability in trace elements distribution in a particular filter, the mean concentration for each element over the five positions (discs) was calculated and each element concentration was normalized to this mean value. Scatter plots of the normalized concentrations were examined for all elements and all sub-samples. We considered that an element was homogeneously distributed if its normalized concentrations in the 45 sub-samples were within +/- 15% of the mean value ranging between 0.85 and 1.15. The study demonstrated that the 12 elements tested showed different distribution pattern. Aluminium, Cu and V showed the most homogeneous pattern while Cd and Ni exhibited the largest departures from the mean value in 13 out of the 45 discs analyzed. No preferential deposition was noticed in any sub-sample. (c) 2005 Elsevier B.V. All rights reserved.
机译:进行了一项研究,以评估使用配备有PM-10采样头的大容量采样器收集的玻璃纤维过滤器上沉积的金属和准金属分布的均匀性。称重装有空气颗粒物(APM)的玻璃纤维过滤器(有效表面约500 cm(2)),然后将每个过滤器切成5个直径为6.5 cm的小圆盘。使用硝酸,高氯酸和氢氟酸的混合物,通过酸辅助微波(MW)消化将每个圆盘矿化。通过轴向观察电感耦合等离子体发射光谱法(ICP OES)进行分析,考虑的元素为:Al,As,Cd,Cr,Cu,Fe,Mn,Ni,Pb,Sb,Ti和V。该程序通过分析标准参考材料NIST 1648(城市颗粒物)进行。作为比较特定过滤器中痕量元素分布的可能变化的一种方式,计算了五个位置(圆盘)上每个元素的平均浓度,并将每个元素浓度归一化为该平均值。检查所有元素和所有子样品的归一化浓度散点图。我们认为,如果元素在45个子样本中的归一化浓度在0.85至1.15之间的平均值的+/- 15%之内,则该元素是均匀分布的。研究表明,测试的12种元素显示出不同的分布模式。在分析的45个圆盘中,铝,铜和钒显示出最均匀的图案,而镉和镍显示出与平均值的最大偏差。在任何子样本中均未发现优先沉积。 (c)2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号