首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Sulfonylcalix[4]arenetetrasulfonate as pre-column chelating reagent for selective determination of aluminum(III), iron(III), and titanium(IV) by ion-pair reversed-phase high-performance liquid chromatography with spectrophotometric detection
【24h】

Sulfonylcalix[4]arenetetrasulfonate as pre-column chelating reagent for selective determination of aluminum(III), iron(III), and titanium(IV) by ion-pair reversed-phase high-performance liquid chromatography with spectrophotometric detection

机译:磺酰基杯[4]亚芳基四磺酸盐作为柱前螯合剂,通过离子对反相高效液相色谱-分光光度检测法选择性测定铝(III),铁(III)和钛(IV)

获取原文
获取原文并翻译 | 示例
           

摘要

Sulfonylcalix[4]arenetetrasulfonate (SO_2CAS) has been examined as a pre-column chelating reagent for ultratrace determination of metal ions by ion-pair reversed-phase high-performance liquid chromatography with spectrophotometric detection. Metal ions were converted into the SO_2CAS chelates in an acetic buffer solution (pH 4.7). The chelates were injected onto a n-octadecylsilanized silica-type Chromolith~(TM) Performance RP-18e column and were eluted using a methanol (50 wt.%)-water eluent (pH 5.6) containing tetra-n-butylammonium bromide (7.0 mmol kg~(-1)), acetate buffer (5.0 mmol kg~(-1)), and disodium ethylendiamine-N,N,N',N'-tetraacetate (0.10 mmol kg~(-1)). Under the conditions used, Al(III), Fe(III), and Ti(IV) were selectively detected among 21 kinds of metal ions [Al(III), Ba(II), Be(II), Ca(II), Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Ga(III), Hf(IV), In(III), Mg(II), Mn(II), Mo(VI), Ni(II), Pb(II), Ti(IV), V(V), Zn(II), and Zr(IV)]. The detection limits on a 3 blank basis were 8.8 nmol dm~(-3) (0.24 ng cm~(-3)) for Al(III), 7.6 nmol dm~(-3) (0.42 ng cm~(-3)) for Fe(III), and 17 nmol dm~(-3) (0.80 ng cm~(-3)) for Ti(IV). The practical applicability of the proposed method was checked using river and tap water samples.
机译:磺酰基杯[4]亚芳基四磺酸盐(SO_2CAS)已作为离子对反相高效液相色谱-分光光度检测法检测的一种超前测定金属离子的柱前螯合剂。金属离子在乙酸缓冲溶液(pH 4.7)中转化为SO_2CAS螯合物。将螯合物注入到正十八烷基硅烷化的二氧化硅型ChromolithTM Performance RP-18e色谱柱上,并使用含有四正丁基溴化铵(7.0)的甲醇(50 wt%)-水洗脱液(pH 5.6)洗脱醋酸盐缓冲液(5.0 mmol kg〜(-1)),乙二胺二胺-N,N,N',N'-四乙酸二钠(0.10 mmol kg〜(-1))。在所使用的条件下,在21种金属离子中分别检测到Al(III),Fe(III)和Ti(IV),[Al(III),Ba(II),Be(II),Ca(II), Cd(II),Co(II),Cr(III),Cu(II),Fe(III),Ga(III),Hf(IV),In(III),Mg(II),Mn(II), Mo(VI),Ni(II),Pb(II),Ti(IV),V(V),Zn(II)和Zr(IV)]。 3个空白的检测限为Al(III)为8.8 nmol dm〜(-3)(0.24 ng cm〜(-3)),7.6 nmol dm〜(-3)(0.42 ng cm〜(-3)对于Fe(III)为),对于Ti(IV)为17 nmol dm〜(-3)(0.80 ng cm〜(-3))。使用河流和自来水样本检查了该方法的实际适用性。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号