首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Determination of polycyclic aromatic hydrocarbons in water samples using online microextraction by packed sorbent coupled with gas chromatography-mass spectrometry
【24h】

Determination of polycyclic aromatic hydrocarbons in water samples using online microextraction by packed sorbent coupled with gas chromatography-mass spectrometry

机译:填充吸附剂-气相色谱-质谱联用在线微萃取测定水样中的多环芳烃

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A fully automated microextraction by packed sorbents (MEPS) coupled with large volume injection gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of eight polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Naphthalene (Nap), pyrene (Pyr), anthracene, acenaphthylene, phenanthrene, fluoranthene (Flr), fluorene and acenaphthene were the PAHs studied. The performance of the microextraction-GC-MS protocol was compared with solid phase extraction (SPE) and GC-MS analysis. Under optimized experimental conditions, the methods were linear for all analytes in the following ranges: 0.05-2.0 μg L ~(-1) (MEPS) and 0.25-10.0 μg L ~(-1) (SPE). The correlation coefficients (R ~2) were in the range 0.9965-0.9997 (MEPS) and 0.9978-0.9998 (SPE) for all the analytes. Limits of detection (LODs) for 2 mL samples (MEPS) ranged from 0.8 ng L ~(-1) to 8.2 ng L ~(-1). LODs for 50 mL samples (SPE) were between 4.8 ng L ~(-1) and 35.9 ng L ~(-1). The two methods were successfully applied to the determination of the 8 PAHs in environmental waters, with recoveries in the range of 70-117% (MEPS) and 72-134% (SPE) for a real spiked sample. The two sample preparation processes showed good repeatabilities with intra-day relative standard deviations below 14.0% (MEPS) and 14.6% (SPE). Nap, Flr and Pyr were found in a river water sample.
机译:已经开发了一种全自动吸附填料吸附微萃取技术(MEPS)和大体积进样气相色谱质谱联用技术(GC-MS),用于测定环境水样品中的八种多环芳烃(PAH)。萘(Nap),pyr(Pyr),蒽,,菲,荧蒽(Flr),芴和是被研究的多环芳烃。将微萃取-GC-MS方案的性能与固相萃取(SPE)和GC-MS分析进行了比较。在优化的实验条件下,该方法对于以下范围内的所有分析物都是线性的:0.05-2.0μgL〜(-1)(MEPS)和0.25-10.0μgL〜(-1)(SPE)。所有分析物的相关系数(R〜2)在0.9965-0.9997(MEPS)和0.9978-0.9998(SPE)范围内。 2 mL样品(MEPS)的检出限(LOD)为0.8 ng L〜(-1)至8.2 ng L〜(-1)。 50 mL样品(SPE)的LOD在4.8 ng L〜(-1)和35.9 ng L〜(-1)之间。两种方法已成功应用于环境水中8种多环芳烃的测定,实际加标样品的回收率在70-117%(MEPS)和72-134%(SPE)之间。两种样品制备过程显示出良好的重复性,日内相对标准偏差分别低于14.0%(MEPS)和14.6%(SPE)。在河水样品中发现了Nap,Flr和Pyr。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号