Isosorbide dinitrate (ISDN) is reduced voltammetrically at gold working electrode surface in aqueous sodium sulfite solution and produces a voltammogram with its peak current proprotional to the concentration of ISDN in the range of 1.3-2340 #mu#g ml~(-1). Sodium sulfite is used as supporting electrolyte and oxygen removing agent and, therefore, no nitrogen gas purging for elimination of soluble oxygen in, the sample solution is required. The limit of detection (LOD) of the method is 0.0838 #mu#g ml~(-1) and the relative standard deviation (R.S.D.) of 24 replicate determination of 52 #Mu#g ml~(-1) of ISDN is 3.60%. The method is used for quantitative analysis of ISDN in arterial plasma, synthetic serum and pharmaceutical dosage form. The results are compared with those obtained from GC determination method. The method is sensitive and requires little sample preparation in a wide concentration range.
机译:亚硝酸异山梨酯(ISDN)在亚硫酸钠水溶液中的金工作电极表面上伏安还原,并产生伏安图,其峰值电流与ISDN浓度成正比,范围为1.3-2340#mu#g ml〜(-1)。亚硫酸钠用作辅助电解质和除氧剂,因此,不需要氮气吹扫来消除样品溶液中的可溶性氧。该方法的检出限(LOD)为0.0838#mu#g ml〜(-1),ISDN的52#Mu#g ml〜(-1)的24次重复测定的相对标准偏差(RSD)为3.60。 %。该方法用于动脉血浆,合成血清和药物剂型中ISDN的定量分析。将结果与通过GC测定方法获得的结果进行比较。该方法灵敏,在宽浓度范围内几乎不需要样品制备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号