The development of a slurry sampling method for the determination of calcium,copper,iron,magnesium and zinc in fish tissue samples by flame atomic absorption spectrometry is described.In comparison with microwave-assisted digestion,the proposed method is simple,requires short time and eliminates total sample dissolution before analysis.Suspension medium was optimized for each analyte to obtain quantitative recoveries from fish tissue samples without matrix interferences.Nevertheless,iron recoveries higher than 46% were not found.Treatment of samples slurried in nitric acid by microwave irradiation for 15-30 s at 75-285 W permitted to achieve efficient recoveries for calcium,iron,magnesium and zinc.Further improvement in the matrix effects for iron determination was accomplished by the use of an additional step of short microwave-assisted suspension treatment.However,standard addition method was required for calcium and copper determination,being necessary hydrochloric acid as suspension medium for the last one.Although copper could not be determined in the certified reference material using microwave-assisted digestion,the accuracy of the slurry sampling method was verified for all the investigated analytes.Detection limits were 22.8 +- 8.0,0.884 +- 0.092,5.07 +- 0.76,35.5 +- 0.7 and 1.17 +- 0.04 mu g g-1 for calcium,copper,iron,magnesium and zinc,respectively.The standard deviations obtained using slurry sampling method and microwave-assisted digestion were not significantly different,and the mean relative standard deviation of the over-all method (n = 3) of the slurry sampling method for different concentration levels was below 12%.
机译:介绍了一种用火焰原子吸收光谱法测定鱼组织样品中钙,铜,铁,镁,锌的浆料采样方法的发展。与微波消解相比,该方法简便,耗时短,操作简便。消除了样品在分析之前的总溶解度。针对每种分析物优化了悬浮介质,从鱼类组织样品中获得了定量回收率,而没有基质干扰。然而,铁回收率未超过46%。通过微波辐射在硝酸中制浆的样品处理15次在75-285 W的温度下-30 s可以实现钙,铁,镁和锌的有效回收率。通过使用额外的短时间微波辅助悬浮处理,可以进一步提高铁测定的基质效应。钙和铜的测定需要标准加入方法,其中必须添加盐酸作为悬浮剂在最后一种介质中使用n。尽管无法通过微波消解在认证的参考材料中测定铜,但已对所有研究的分析物验证了浆料采样方法的准确性。检测限为22.8 +-8.0,0.884 +-钙,铜,铁,镁和锌分别为0.092、5.07 +-0.76、35.5 +-0.7和1.17 +-0.04μg g-1。使用浆液采样法和微波辅助消解获得的标准偏差不显着在不同浓度水平下,泥浆取样方法的总体方法(n = 3)的平均相对标准偏差低于12%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号