The electrocatalytic activity of a CuO flower-like nanostructured electrode was investigated in terms of its application to enzyme-less amperometric H2O2 sensors. The CuO nanoflowers film was directly formed by chemical oxidation of copper foil under hydrothermal condition and then used as active electrode material of non-enzymatic electrochemical sensors for H2O2 detection under alkaline conditions. The sensitivity of the sensor with CuO nanoflowers electrode was 88 4 mu A/mM cm(2) with a linear response in the range from 4.25 x 10(-5) to 4 x 10(-2) M and a detection limit of 0.167 mu M (S/N = 3). Excellent electrocatalytic activity, large surface-to-volume ratio and efficient electron transport property of CuO nanoflowers electrode have enabled stable and highly sensitive performance for the non-enzymatic H2O2 sensor.
机译:研究了CuO花状纳米结构电极在无酶电流型H2O2传感器中的电催化活性。通过在水热条件下对铜箔进行化学氧化直接形成CuO纳米花膜,然后将其用作非酶电化学传感器在碱性条件下检测H2O2的活性电极材料。具有CuO纳米花电极的传感器的灵敏度为88 4μA/ mM cm(2),线性响应范围为4.25 x 10(-5)至4 x 10(-2)M,检测极限为0.167 μM(S / N = 3)。 CuO纳米花电极具有出色的电催化活性,大的表面体积比和高效的电子传输性能,从而使非酶H2O2传感器具有稳定且高度灵敏的性能。