首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Determination of folic acid by chemiluminescence based on peroxomonosulfate-cobalt(II) system
【24h】

Determination of folic acid by chemiluminescence based on peroxomonosulfate-cobalt(II) system

机译:过氧单硫酸盐-钴(II)体系化学发光法测定叶酸

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Based on the chemiluminescence (CL) phenomena of folic acid in peroxomonosulfate-cobalt(II) system, a rapid and sensitive CL method was developed for determination of folic acid in pharmaceutical preparations and its urinary metabolism processes. Under the optimum conditions, the relative CL intensity was linear over the concentration ranging from 10(-9) to 8 x 10(-7) mol L-1 (R-2 = 0.9991) with a detection limit as low as 6 x 10(-10) mol L-1 (S/N = 3) and relative standard deviation was 2.63% for 2 x 10(-8) mol L-1 folic acid (n = 11). This method has been successfully applied to the determination of folic acid in tablets and human urine. The blank CL emission was yielded owing to the formation of singlet oxygen molecular pair from the quenching experiment of 1,4-diazabicyclo[2.2.2] octane, and pterine-6-carboxylic acid might be the degradation intermediate in this system and it also acts an energy acceptor and sensitizes the chemiluminescence based on the studies of the CL and fluorescence spectra. (c) 2007 Elsevier B.V. All rights reserved.
机译:基于过氧单硫酸盐-钴(II)体系中叶酸的化学发光(CL)现象,开发了一种快速灵敏的CL方法,用于测定药物制剂及其尿代谢过程中的叶酸。在最佳条件下,相对CL强度在10(-9)至8 x 10(-7)mol L-1(R-2 = 0.9991)的浓度范围内呈线性,检出限低至6 x 10 (-10)mol L-1(S / N = 3),相对标准偏差为2 x 10(-8)mol L-1叶酸(n = 11)为2.63%。该方法已成功应用于片剂和人尿中叶酸的测定。通过1,4-二氮杂双环[2.2.2]辛烷的淬灭实验,由于形成单线态氧分子对而产生了空白的CL发射,而蝶呤-6-羧酸可能是该系统的降解中间体,而且基于CL和荧光光谱的研究,其充当能量受体并敏化化学发光。 (c)2007 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号