Irreversible electroporation: Evaluation of nonthermal and thermal ablative capabilities in the porcine kidney

机译:不可逆电穿孔:评估猪肾脏的非热和热消融能力

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To compare the renal ablative capabilities of nonthermal irreversible electroporation (NT-IRE) with those of thermal irreversible electroporation (T-IRE) in a porcine model. Materials and Methods: A total of 24 laparoscopic renal ablations were performed in 12 pigs using a novel generator capable of alternately delivering NT-IRE and T-IRE. Each pig underwent unilateral interpolar ablation straddling the renal pelvis and lower pole ablation, using a single modality. The pigs were killed at 24 hours and 7 and 21 days. Basic serum laboratory tests, cardiac enzyme levels, and retrograde pyelograms were obtained before and immediately after ablation and at death. Ablation adequacy and lesion size were assessed by histologic examination. Results: All procedures were successfully completed without complications. For NT-IRE vs T-IRE, the median lesion size (long axis) at 24 hours, 7 days and 21 days was 3.0 vs 3.3 cm (P = 1.0), 2.5 vs 3.9 cm (P =.04), and 1.2 vs 2.8 cm (P =.03), respectively. Prolonged urinary extravasation and collecting system scarring were observed only for T-IRE. Both NT-IRE and T-IRE ablated the renal tissue adequately. NT-IRE was characterized by acute hemorrhagic necrosis, sparing the large blood vessels and extracellular matrix, and T-IRE by coagulation necrosis with associated moderate inflammation. Conclusion: NT-IRE and T-IRE both safe and effectively ablate normal porcine kidneys. NT-IRE created smaller lesions with unique histologic characteristics. Significant collecting system injury occurred with T-IRE. Additional preclinical evaluation aimed at optimizing the ablation protocols is needed. ? 2013 Elsevier Inc. All Rights Reserved.
机译:目的:在猪模型中比较非热不可逆电穿孔(NT-IRE)和热不可逆电穿孔(T-IRE)的肾脏消融能力。材料和方法:使用能够交替输送NT-IRE和T-IRE的新型发生器,对12头猪进行了总共24例腹腔镜肾切除术。每只猪都采用单一方式进行跨肾盂和下极消融的单侧极间消融。在24小时,7和21天将猪杀死。在消融之前和之后以及死亡时获得了基本的血清实验室测试,心脏酶水平和逆行肾盂造影图。通过组织学检查评估消融的充分性和病变的大小。结果:所有手术均成功完成,无并发症。对于NT-IRE与T-IRE,在24小时,7天和21天时的中位病变大小(长轴)分别为3.0 vs 3.3 cm(P = 1.0),2.5 vs 3.9 cm(P = .04)和1.2与2.8厘米(P = .03)分别对应。仅对于T-IRE,观察到长时间的尿液渗出和收集系统瘢痕形成。 NT-IRE和T-IRE均可充分消融肾组织。 NT-IRE的特征是急性出血性坏死,保留大血管和细胞外基质,T-IRE的特征是凝血坏死并伴有中度炎症。结论:NT-IRE和T-IRE均可安全有效地消融正常猪肾脏。 NT-IRE可产生具有独特组织学特征的较小病变。 T-IRE严重损坏了采集系统。需要进行旨在优化消融方案的其他临床前评估。 ? 2013 Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号