首页> 外文期刊>Urology >Monitoring renal function: a prospective study comparing camera-based technetium-99m mercaptoacetyltriglycine clearance and creatinine clearance.
【24h】

Monitoring renal function: a prospective study comparing camera-based technetium-99m mercaptoacetyltriglycine clearance and creatinine clearance.

机译:监测肾功能:一项前瞻性研究,比较基于相机的tech 99m巯基乙酰基三甘氨酸清除率和肌酐清除率。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: To determine the value and limitations of technetium-99m mercaptoacetyltriglycine (MAG3) clearance measurements obtained using a gamma camera (camera-based MAG3 clearance), a prospective study was conducted to evaluate the reproducibility of camera-based MAG3 clearance compared with that of conventional creatinine clearance. METHODS: A total of 24 male patients with stable renal function were entered into the study. The mean age was 66.5 +/- 7.9 years, and the mean serum creatinine was 1.38 +/- 0.57 mg/dL. MAG3 renal scans and 24-hour creatinine clearance measurements were performed 11 +/- 8 days apart. A camera-based MAG3 clearance was obtained at each MAG3 scan; no blood samples were required. Bland-Altman plots were constructed to assist in data analysis. RESULTS: The Pearson correlation for the first and second camera-based MAG3 clearances (mean 151 versus 158 mL/min/1.73 m2, respectively) was 0.965 compared with 0.729 for the two creatinine clearance measurements (mean 62 versus 72 mL/min/1.73 m2, respectively). Even with the omission of two outliers, the creatinine clearance would have to change by 58.2% compared with the baseline measurement before the clinician could be confident the change exceeded the error of measurement. In contrast, the change required for the camera-based MAG3 clearance was 30.8%. CONCLUSIONS: The results of this study have demonstrated that MAG3 clearance obtained using a camera-based technique shows greater precision than the conventional creatinine clearance and is superior to the conventional creatinine clearance for monitoring changes in renal function.
机译:目的:为确定使用伽马相机(基于相机的MAG3清除率)获得的99m巯基乙酰基三甘氨酸(MAG3)清除率测量的价值和局限性,进行了一项前瞻性研究,以评估基于相机的MAG3清除率与可重复使用的MAG3清除率的可重复性。常规肌酐清除率。方法:总共24名肾功能稳定的男性患者进入研究。平均年龄为66.5 +/- 7.9岁,平均血清肌酐为1.38 +/- 0.57 mg / dL。间隔11 +/- 8天进行MAG3肾脏扫描和24小时肌酐清除率测量。每次MAG3扫描都获得了基于相机的MAG3清除率;无需血液样本。构造了Bland-Altman图以协助数据分析。结果:基于第一个和第二个基于相机的MAG3清除率(分别为151 vs 158 mL / min / 1.73 m2)的Pearson相关性是0.965,而两次肌酐清除率测量值(分别为62 vs. 72 mL / min / 1.73)的Pearson相关性是0.729。分别为m2)。即使忽略了两个异常值,肌酐清除率也必须与基线测量值相比改变58.2%,然后临床医生才能确信该变化超出了测量误差。相反,基于相机的MAG3间隙所需的更改为30.8%。结论:这项研究的结果表明,使用基于相机的技术获得的MAG3清除率比常规肌酐清除率更高,并且在监测肾功能变化方面优于常规肌酐清除率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号