首页> 外文期刊>Urology >Optimizing renal cortical neoplasm tissue sampling through a modified biopsy technique: laboratory experience and initial clinical experience.
【24h】

Optimizing renal cortical neoplasm tissue sampling through a modified biopsy technique: laboratory experience and initial clinical experience.

机译:通过改良的活检技术优化肾皮质肿瘤组织采样:实验室经验和初步临床经验。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: We evaluated 11 currently available biopsy devices using a standard and a novel renal biopsy technique in a porcine model. We then applied our laboratory findings to clinical practice to improve our biopsy results during laparoscopic renal cryoablation procedures. METHODS: A total of 11 biopsy devices were applied to live porcine renal tissue using two different techniques. In groups 1 and 2, the biopsy devices were deployed external to the renal tissue and in a standard manner after insertion into the renal tissue, respectively. Ten biopsies were performed for each condition and with each device. The biopsy quality metrics included sample core length and width and number of glomeruli and vessels in each sample. Subsequently, we confirmed our laboratory finding regarding the optimal biopsy technique during 10 sequential laparoscopic renal cryoablation procedures. During these procedures, each renal mass underwent the standard and modified biopsy techniques. RESULTS: In the animal investigation, a total of 220 biopsies were performed. Regarding the biopsy technique, the mean core length for groups 1 and 2 was 7.32 and 4.91 mm (P <0.01) and the mean number of glomeruli was 7.6 and 4.2 (P <0.01), respectively. Clinically, 10 patients successfully underwent renal cryoablation in conjunction with the two renal biopsy groups. In all 10 cases, between the two biopsies, a histopathologic diagnosis was successfully obtained. The preablation standard and preablation modified biopsy technique established a diagnosis 7 of 10 and 9 of 10 times, respectively. CONCLUSIONS: Our preliminary laboratory and clinical data have demonstrated the effectiveness and safety of the modified biopsy technique.
机译:目的:我们在猪模型中使用标准和新颖的肾脏活检技术评估了11种当前可用的活检设备。然后,我们将实验室检查结果应用于临床实践,以改善腹腔镜肾冷冻消融手术期间的活检结果。方法:采用两种不同的技术将共11种活检装置用于活猪肾组织。在第1组和第2组中,活检装置分别在插入肾组织后以标准方式部署在肾组织外部。针对每种情况和每种设备进行了十次活检。活检质量指标包括每个样本的样本核心长度和宽度以及肾小球和血管的数量。随后,我们证实了我们的实验室发现,涉及在连续10例腹腔镜肾冷冻消融术中的最佳活检技术。在这些程序中,每个肾脏肿块均接受了标准和改良的活检技术。结果:在动物研究中,共进行了220次活检。就活检技术而言,第1组和第2组的平均芯长分别为7.32和4.91 mm(P <0.01),肾小球的平均数分别为7.6和4.2(P <0.01)。临床上,成功地将10例患者与两个肾脏活检组一起进行了肾脏冷冻消融术。在两次活检之间的所有10例病例中,均成功获得了组织病理学诊断。消融标准和消融改良活检技术分别建立了10次诊断7次和10次诊断。结论:我们的初步实验室和临床数据证明了改良活检技术的有效性和安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号