首页> 外文期刊>Ultrasound in obstetrics & gynecology: the official journal of the International Society of Ultrasound in Obstetrics and Gynecology >Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.
【24h】

Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

机译:用于执行和分析3D / 4D会阴超声成像和观察者间可靠性研究的学习过程。

获取原文
获取原文并翻译 | 示例
           

摘要

To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners.This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners.For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67).3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright ? 2012 ISUOG. Published by John Wiley & Sons, Ltd.
机译:评估学习过程以获取静止,盆底肌肉(PFM)收缩和Valsalva动作时提肛裂孔(LH)尺寸的经会阴超声三维和三维(3D / 4D)尺寸,并分析超声以及在两名独立的超声检查员之间进行观察者间可靠性研究,这是一项前瞻性研究,涉及22名女性。我们监测了经验不足的检查员(IE)进行3D / 4D会阴超声检查并分析其量的学习过程。该检查包括在三个PFM收缩和三个Valsalva动作期间获取体积。 LH尺寸在轴向平面中确定。通过使用类内相关系数估计IE和有经验的考官(E)之间的一致性来记录学习过程。以10次超声检查和分析量为单位计算一致性。学习过程完成后,计算了这两名独立检查员之间的观察者间可靠性。对于E所获得的前10个超声体积的脱机分析,除LH测量外,所有LH测量均获得了E和IE的良好至非常好的一致性左右提肛间隙和耻骨弓。对于接下来的10个分析体积,所有LH测量的一致性都得到了改善。然后,通过IE重新评估IE和E获得的体积,发现所有LH测量的一致性都很好,表明体积采集的一致性。观察者之间的可靠性研究表明,除耻骨弧(ICC = 0.67)外,所有LH测量均具有出色的ICC值(ICC,0.81-0.97)。3D/ 4D会阴超声是一项可靠的技术,可在短时间内学习。版权? 2012年ISUOG。由John Wiley&Sons,Ltd.出版

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号