首页> 外文期刊>Ultrasound in Medicine and Biology >TEMPORAL COMPOUNDING: A NOVEL IMPLEMENTATION AND ITS IMPACT ON QUALITY AND DIAGNOSTIC VALUE IN ECHOCARDIOGRAPHY
【24h】

TEMPORAL COMPOUNDING: A NOVEL IMPLEMENTATION AND ITS IMPACT ON QUALITY AND DIAGNOSTIC VALUE IN ECHOCARDIOGRAPHY

机译:时间复合:心电图学的新实现及其对质量和诊断价值的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Temporal compounding can be used to suppress acoustic noise in transthoracic cardiac ultrasound by spatially averaging partially decorrelated images acquired over consecutive cardiac cycles. However, the reliable spatial and temporal alignment of the corresponding frames in consecutive cardiac cycles is vital for effective implementation of temporal compounding. This study introduces a novel, efficient, accurate and robust technique for the spatiotemporal alignment of consecutive cardiac cycles with variable temporal characteristics. Furthermore, optimal acquisition parameters, such as the number of consecutive cardiac cycles used, are derived. The effect of the proposed implementation of temporal compounding on cardiac ultrasound images is quantitatively assessed (32 clinical data sets providing a representative range of image qualities and diagnostic values) using measures such as tissue signal-to-noise ratio, chamber signal-to-noise ratio, tissue/chamber contrast and detectability index, as well as a range of clinical measurements, such as chamber diameter and wall thickness, performed during routine echocardiographic examinations. Temporal compounding (as implemented) consistently improved the image quality and diagnostic value of the processed images, when compared with the original data by: (i) increasing tissue and cavity signal-to-noise ratios as well as tissue/cavity detectability index, (ii) improving the corresponding clinical measurement repeatability and inter-operator measurement agreement, while (iii) reducing the number of omitted measurements caused by data corruption. (E-mail: A.Perperidis@hw.ac.uk) (C) 2015 World Federation for Ultrasound in Medicine & Biology.
机译:通过对在连续心动周期中获取的部分去相关图像进行空间平均,可以使用时间复合来抑制经胸心脏超声中的声音噪声。然而,连续心动周期中相应帧的可靠空间和时间对齐对于有效实施时间复合至关重要。这项研究介绍了一种新颖,高效,准确和鲁棒的技术,用于具有可变时间特征的连续心动周期的时空对齐。此外,得出最佳采集参数,例如所用连续心动周期的数量。使用组织信噪比,腔室信噪比等方法对拟议实施的时间复合对心脏超声图像的影响进行定量评估(32个临床数据集,提供代表性的图像质量和诊断值范围)比率,组织/腔室对比度和可检测性指数,以及常规超声心动图检查期间进行的一系列临床测量,例如腔室直径和壁厚。与原始数据相比,时间复合(已实施)通过以下方式不断改善了处理后图像的图像质量和诊断价值:(i)增加组织和腔的信噪比以及组织/腔可检测性指标,( ii)改善相应的临床测量可重复性和操作者之间的测量协议,同时(iii)减少因数据损坏而导致的遗漏测量次数。 (电子邮件:A.Perperidis@hw.ac.uk)(C)2015年世界医学和生物学超声联合会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号