首页> 外文期刊>Ultrasound in Medicine and Biology >CLINICAL EVALUATION OF A 3-D AUTOMATIC ANNOTATION METHOD FOR BREAST ULTRASOUND IMAGING
【24h】

CLINICAL EVALUATION OF A 3-D AUTOMATIC ANNOTATION METHOD FOR BREAST ULTRASOUND IMAGING

机译:乳腺超声影像3-D自动标注方法的临床评价

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The routine clinical breast ultrasound annotation method is limited by the time it consumes, inconsistency, inaccuracy and incomplete notation. A novel 3-D automatic annotation method for breast ultrasound imaging has been developed that uses a spatial sensor to track and record conventional B-mode scanning so as to provide more objective annotation. The aim of the study described here was to test the feasibility of the automatic annotation method in clinical breast ultrasound scanning. An ultrasound scanning procedure using the new method was established. The new method and the conventional manual annotation method were compared in 46 breast cancer patients (49 +/- 12 y). The time used for scanning a patient was recorded and compared for the two methods. Intraobserver and inter-observer experiments were performed, and intra-class correlation coefficients (ICCs) were calculated to analyze system reproducibility. The results revealed that the new annotation method had an average scanning time 36 s (42.9%) less than that of the conventional method. There were high correlations between the results of the two annotation methods (r = 0.933, p < 0.0001 for distance; r = 0.995, p < 0.0001 for radial angle). Intra-observer and inter-observer reproducibility was excellent, with all ICCs > 0.92. The results indicated that the 3-D automatic annotation method is reliable for clinical breast ultrasound scanning and can greatly reduce scanning time. Although large-scale clinical studies are still needed, this work verified that the new annotation method has potential to be a valuable tool in breast ultrasound examination. (E-mail: ypzheng@ieee.org) (C) 2016 World Federation for Ultrasound in Medicine & Biology.
机译:常规的临床乳房超声注释方法受其消耗的时间,前后不一致,不准确以及注释不完整的限制。已经开发出一种用于乳房超声成像的新颖的3D自动注释方法,该方法使用空间传感器来跟踪和记录常规B模式扫描,以便提供更客观的注释。本文所述研究的目的是测试自动注释方法在临床乳房超声扫描中的可行性。建立了使用新方法的超声扫描程序。比较了46例乳腺癌患者(49 +/- 12岁)中的新方法和常规手动注释方法。记录用于扫描患者的时间,并比较两种方法。进行了观察者内和观察者间实验,并计算了类内相关系数(ICC)以分析系统的可重复性。结果表明,新注释方法的平均扫描时间比传统方法少36 s(42.9%)。两种标注方法的结果之间具有高度相关性(距离r = 0.933,p <0.0001;径向角度r = 0.995,p <0.0001)。观察者内和观察者间的重复性极佳,所有ICC> 0.92。结果表明3-D自动标注方法对于临床乳房超声扫描是可靠的,并且可以大大减少扫描时间。尽管仍需要进行大规模的临床研究,但这项工作证实了新的注释方法有潜力成为乳房超声检查中的宝贵工具。 (电子邮件:ypzheng@ieee.org)(C)2016年世界医学和生物学超声联合会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号