首页> 外文期刊>Ultrasound in Medicine and Biology >Quantification of regional volume and systolic function of the left ventricle by real-time three-dimensional echocardiography.
【24h】

Quantification of regional volume and systolic function of the left ventricle by real-time three-dimensional echocardiography.

机译:实时三维超声心动图量化左心室的局部容积和收缩功能。

获取原文
获取原文并翻译 | 示例
           

摘要

Real-time three-dimensional (3D) echocardiography (RT-3DE) provides a unique technique to evaluate left ventricular regional function in a 3D format. We aimed to explore whether the left ventricular segmental volume and systolic function is uniform and to establish normal values of volume and systolic function parameters of 16 regions in healthy subjects. RT-3DE was performed in 41 normal subjects and four-dimensional (4D)-left ventricle (LV) analysis software and a TomTec workstation were used to analyze data for regional end-diastolic volume (EDV(R)), regional end-systolic volume (ESV(R)), regional stroke volume (SV(R)), regional ejection fraction (EF(R)), ratio of SV(R) to global SV (SV(R/G)) and ratio of SV(R) to global EDV (EF(R/G)). All regional volume and systolic function parameters were not uniform among the left ventricular walls. They all increased in the order of inferior, posterior, lateral, septal, anterior and antero-septal walls with an increasing trend from the apical, middle to basal segments. The systolic function (EF(R), SV(R/G) and EF(R/G)) of the anterior and antero-septal walls was significantly higher than that of the lateral, inferior and posterior walls. And the intra- and interobserver variability for EDV(R), ESV(R), SV(R/G) and EF(R/G) ranged from 2.9% to 5.8%. In conclusion, the regional volume and systolic function of the left ventricle is not uniform and, therefore, a normal left ventricle cannot be regarded as a symmetric model for assessing the regional systolic function. This information may improve the accuracy of RT-3DE techniques in the assessment of the left ventricular regional function. (E-mail: zhangyun@sdu.edu.cn and yaogh@yahoo.com).
机译:实时三维(3D)超声心动图(RT-3DE)提供了一种独特的技术,可以3D格式评估左心室区域功能。我们旨在探讨健康受试者的左心室节段容积和收缩功能是否一致,并建立16个区域的容积和收缩功能参数的正常值。 RT-3DE在41名正常受试者中进行,并且使用三维(4D)-左心室(LV)分析软件和TomTec工作站来分析区域舒张末期容积(EDV(R)),区域舒张末期的数据体积(ESV(R)),区域卒中体积(SV(R)),区域射血分数(EF(R)),SV(R)与整体SV的比率(SV(R / G))和SV(R R)转换为全局EDV(EF(R / G))。左心室壁之间的所有区域容量和收缩功能参数均不一致。它们均以下,后,外侧,间隔,前壁和前中隔的顺序增加,并且从顶部,中部到基底部分呈增加趋势。前壁和前隔壁的收缩功能(EF(R),SV(R / G)和EF(R / G))明显高于外侧,下壁和后壁。 EDV(R),ESV(R),SV(R / G)和EF(R / G)的观察者内和观察者间变异在2.9%至5.8%之间。总之,左心室的区域容量和收缩功能不均匀,因此,正常的左心室不能被视为评估区域收缩功能的对称模型。此信息可能会提高RT-3DE技术在评估左心室区域功能中的准确性。 (电子邮件:zhangyun@sdu.edu.cn和yaogh@yahoo.com)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号