首页> 外文期刊>Ultrasound in Medicine and Biology >Fetal upper arm volume in predicting intrauterine growth restriction: a three-dimensional ultrasound study.
【24h】

Fetal upper arm volume in predicting intrauterine growth restriction: a three-dimensional ultrasound study.

机译:胎儿上臂容积预测子宫内生长受限:三维超声研究。

获取原文
获取原文并翻译 | 示例
           

摘要

As fetuses with intrauterine growth restriction (IUGR) may have increased risks with perinatal morbidity and mortality, prenatal diagnosis of IUGR is a very important issue in perinatology. To assess the efficacy of fetal upper arm volume in predicting IUGR, we undertook a prospective, cross-sectional study using quantitative three-dimensional (3D) ultrasound (US). In total, 40 fetuses with IUGR and 442 fetuses without IUGR were included for the upper arm volume assessment in utero by 3D US. All the fetuses were singletons and were followed up to delivery to establish whether they were complicated with IUGR or not. Our results showed that fetal upper arm volume assessed by 3D US can differentiate fetuses with IUGR from fetuses without IUGR well. The best predicting threshold for IUGR is at the 10th percentile by upper arm volume. Using the 10th percentile as the cutoff, the sensitivity of fetal upper arm volume in predicting IUGR was 97.5%, with specificity 92.8%, predictive value of positive test 54.9%, predictive value of negative test 99.8% and accuracy 93.1%. Furthermore, upper arm volume is the best parameter for detecting IUGR among the common fetal biometric indices, such as biparietal diameter (BPD), occipitofrontal diameter (OFD), head circumference (HC), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW). In conclusion, fetal upper arm volume assessed by quantitative 3D US can be used to predict fetuses with IUGR antenatally. We believe fetal upper arm volume assessment by 3D US would be a useful test in detecting fetuses with IUGR.
机译:由于胎儿宫内生长受限(IUGR)可能会增加围产期发病率和死亡率的风险,因此IUGR的产前诊断在围产期学中非常重要。为了评估胎儿上臂容积在预测IUGR中的功效,我们使用定量三维(3D)超声(美国)进行了一项前瞻性,横断面研究。通过3D US在子宫内评估了总计40具IUGR的胎儿和442具IUGR的胎儿。所有胎儿均为单胎,并被随访直至分娩,以确定他们是否患有IUGR。我们的结果表明,通过3D US评估的胎儿上臂容积可以很好地区分具有IUGR的胎儿和没有IUGR的胎儿。 IUGR的最佳预测阈值是按上臂容积的第10个百分点。以第10个百分位数作为临界值,胎儿上臂容积预测IUGR的敏感性为97.5%,特异性为92.8%,阳性试验的预测值为54.9%,阴性试验的预测值为99.8%,准确性为93.1%。此外,上臂容积是检测常见胎儿生物特征指标中IUGR的最佳参数,例如双顶径(BPD),枕额径(OFD),头围(HC),腹围(AC),股骨长度(FL)以及估计的胎儿体重(EFW)。总之,通过定量3D US评估的胎儿上臂体积可用于预测产前IUGR的胎儿。我们认为,通过3D US进行胎儿上臂容积评估将是检测IUGR胎儿的有用方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号