首页> 外文期刊>Ultrasound in Medicine and Biology >Erythrocytes, as well as microbubble contrast agents, are important factors in improving thermal and therapeutic effects of high-intensity focused ultrasound.
【24h】

Erythrocytes, as well as microbubble contrast agents, are important factors in improving thermal and therapeutic effects of high-intensity focused ultrasound.

机译:红细胞以及微泡造影剂是改善高强度聚焦超声的热和治疗效果的重要因素。

获取原文
获取原文并翻译 | 示例
           

摘要

Erythrocytes, as well as microbubble contrast agents, are important factors in improving thermal effect of high-intensity focused ultrasound (US), or HIFU, and increasing the coagulation volume produced by HIFU irradiation. In vitro experiments used human plasma with various concentrations of human erythrocytes in combination with or without Levovist(R). In vivo experiments used eight Japan white rabbits with three degrees of anemia. Using a 2.17-MHz transducer, HIFU was applied for 60 s, and the temperature rise and the volume of coagulation necrosis was evaluated. There was a significant correlation between the HIFU-induced temperature rise and hematocrit, with a correlation coefficient of 0.998 (p = 0.0001). Although the temperature rise was smaller at low hematocrit, it was significantly increased by adding Levovist(R) in the suspension (p < 0.01). The mean volume of coagulation necrosis was significantly greater in the rabbits with higher hematocrits (p < 0.01), and that in the moderate anemia group was significantly increased by using Levovist(R) (p < 0.01). (E-mail: ).
机译:红血球以及微泡造影剂是改善高强度聚焦超声(US)或HIFU的热效应以及增加HIFU照射产生的凝结量的重要因素。体外实验使用了具有或不具有Levovist的具有各种浓度的人红细胞的人血浆。体内实验使用了八只具有三个贫血程度的日本白兔。使用2.17 MHz传感器,施加HIFU 60 s,评估温度升高和凝血坏死体积。 HIFU引起的温度升高与血细胞比容之间存在显着相关性,相关系数为0.998(p = 0.0001)。尽管在低血细胞比容下温度升高较小,但通过在悬浮液中添加Levovist(R)可以显着提高温度升高(p <0.01)。血细胞比容高的兔子的平均凝血坏死体积更大(p <0.01),而使用Levovist®显着增加了中度贫血组的血浆坏死体积(p <0.01)。 (电子邮件:)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号