首页> 外文期刊>Ultrasound in Medicine and Biology >The effect of 40 kHz ultrasound on tissue plasminogen activator-induced clot lysis in three in vitro models.
【24h】

The effect of 40 kHz ultrasound on tissue plasminogen activator-induced clot lysis in three in vitro models.

机译:在三个体外模型中,40 kHz超声对组织纤溶酶原激活物诱导的血块溶解的影响。

获取原文
获取原文并翻译 | 示例

摘要

In a previous study, high-frequency ultrasound (US) (3 MHz) was shown to enhance in vitro fibrinolysis through enhanced supply of plasminogen to the clot surface. The application of high-frequency US is limited in vivo, however, due to tissue heating. We continued our research using low-frequency US with less tissue heating and improved penetration of the US. Three different in vitro models, internal plasma clot lysis and external lysis with compacted and noncompacted plasma clots, were used to determine the magnitude of the effect of low-frequency US (40 kHz; 0.5 W/cm(2)) on tissue plasminogen activator-induced lysis and to elucidate the mechanisms behind the effect. US enhanced lysis in all three models, with the largest effects (fourfold) being in the compacted plasminogen-poor clot model. Plasminogen supply to the clot surface was again shown to be an important contributor to US-enhanced lysis. (E-mail: ).
机译:在先前的研究中,高频超声(US)(3 MHz)被证明可通过增加凝块表面纤溶酶原的供应来增强体外纤维蛋白溶解。然而,由于组织加热,高频超声的应用在体内受到限制。我们继续使用低频US进行研究,减少组织发热并提高US的渗透率。三种不同的体外模型,即内部血浆凝块裂解和具有压缩和非压缩血浆凝块的外部裂解,用于确定低频US(40 kHz; 0.5 W / cm(2))对组织纤溶酶原激活剂的影响程度诱导的裂解并阐明其背后的机制。 US在所有三个模型中均增强了裂解作用,其中致密纤溶酶原-贫血凝块模型的效果最大(四倍)。再次证明向凝块表面的纤溶酶供应是美国增强裂解的重要因素。 (电子邮件:)。