首页> 外文期刊>Quintessence international >Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings.
【24h】

Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings.

机译:预备角度对CAD / CAM制造的氧化锆冠顶盖边缘和内部配合的影响。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: To evaluate the effect of different preparation angles on the marginal and internal fit of zirconia single-crown copings. METHOD AND MATERIALS: Three ivorine maxillary right first molars were prepared with preparation angles of 4, 8, and 12 degrees. Impressions were made of each abutment tooth to obtain 20 specimens per group. The copings were manufactured by a CAD/CAM system and milled from semi-sintered zirconia blanks. After sintering, 10 copings were randomly chosen from each group and adapted by a dental technician. All 60 copings were cemented with glass ionomer on the master casts. After embedding, all specimens were cross-sectioned. Both marginal and internal fit were evaluated under an optical microscope. A 1-way analysis of variance (ANOVA) and a nonparametric test (Mann-Whitney U) were used to compare data (a = .05). RESULTS: The 4-degree copings showed a mean marginal gap of 91 microm (+/- 15) before and 67 microm (+/- 8) after adaptation; the 8-degree group exhibited a mean marginal gap of 82 microm (+/- 13) before and 67 microm (+/- 11) after adaptation; the 12-degree specimens showed 50 microm (+/- 6) before and 46 microm (+/- 6) after adaptation. Adaptation led to a significant improvement of specimens from the 4-degree and 8-degree groups, while no statistical difference could be observed among 12-degree specimens before and after adaptation. CONCLUSION: The highest marginal gaps were found in the 4- and 8-degree groups. In the group with 12-degree preparation angle, additional adaptation did not improve the fit and can be considered unnecessary under the conditions of this study.
机译:目的:评估不同制备角度对氧化锆单冠顶盖的边缘和内部配合的影响。方法和材料:准备了三个角质分别为4度,8度和12度的上颌右牙槽牙。对每个基牙进行印象,每组获得20个样本。顶盖通过CAD / CAM系统制造,并由氧化锆半烧结坯料铣削而成。烧结后,从每组中随机选择10个顶盖,并由牙科技师进行调整。将所有60个顶盖都用玻璃离聚物粘接在主铸模上。包埋后,将所有样品切开。在光学显微镜下评估边缘和内部拟合。使用方差单向分析(ANOVA)和非参数检验(Mann-Whitney U)来比较数据(a = .05)。结果:四度应对显示适应前91微米(+/- 15)和适应后67微米(+/- 8)的平均边缘间隙。 8度组的平均边缘间隙在适应之前为82微米(+/- 13),在适应之后为67微米(+/- 11)。 12度标本显示适应前为50微米(+/- 6),适应后为46微米(+/- 6)。适应导致4度和8度组样本的显着改善,而适应前后12度样本之间没有统计学差异。结论:在4度和8度组中,边缘间隙最高。在具有12度预备角的组中,进行额外的适应并不能改善合身性,因此在本研究条件下可以认为是不必要的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号