...
首页> 外文期刊>Quintessence international >In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
【24h】

In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions

机译:对获得全牙弓印模的常规方法和数字方法的准确性进行体外评估

获取原文
获取原文并翻译 | 示例

摘要

Objective: To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Method and Materials: Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. Results: A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 mu m (VSE) to 60.2 mu m (POE), and precision ranged from 12.3 mu m (VSE) to 66.7 mu m (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conclusions: Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.
机译:目的:研究使用体外参考模型获得全口模印模的传统和数字印模方法的准确性。方法和材料:八种不同的常规物质(聚醚POE;乙烯基硅氧烷醚VSE;直接可扫描乙烯基硅氧烷醚VSES;不可逆水胶体ALG)和数字设备(CEREC Bluecam CER; CEREC Omnicam OC; Cadent iTero ITE; ITE; Lava COS,使用高精度参考扫描仪,从具有已知形态的参考模型中获得LAV)全拱形印象。然后将获得的印象与参考模型的原始几何形状进行比较,并在每个测试组中进行比较。结果:使用有符号最近邻方法对模型的表面进行点对点测量,得出的印象数与原始模型之间的差异(真实性)的平均值(平均值为10%-90%)/ 2个百分点作为测试组内展示次数之间的差异(精确度)。真实值范围从11.5微米(VSE)到60.2微米(POE),精度范围从12.3微米(VSE)到66.7微米(POE)。在测试组中,VSE,VSES和CER显示出最高的真实性和准确性。偏差模式随压印方法而变化。传统印象显示,除POE和ALG外,所有组的整个牙弓的准确性都很高。结论:常规和数字印模方法在全拱形精度方面存在差异。数字印象系统揭示了全拱形模型的较高局部偏差。与高精度的传统印模技术相比,数字口内印模系统没有显示出更高的精度。但是,在使用正确的扫描技术的适应症范围内,它们可提供出色的临床效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号