Bioimpedance analysis was used to measure conductive tissue extracellular fluid (ECF) volume changes in the residual limbs of four unilateral transtibial amputee subjects during standing and walking conditions. Results showed that all residual limbs experienced ECF volume decreases during 5min standing intervals. During 5min of walking immediately after a standing interval, the residual limbs of healthy subjects increased in ECF volume while those of diseased subjects, one with peripheral vascular disease and another with cardiovascular insufficiency and a high-salt intake, decreased. One subject demonstrated less absolute value ECF volume change during standing and walking at 12 months post-surgical revision compared with at six months. Presentation of bioimpedance data to patients improved compliance to practitioner recommendations and patient understanding. Results were useful towards clinical assessment, patient education, and decision-making about treatment.
机译:生物阻抗分析用于测量站立和行走条件下四名单侧经截肢者的残肢中导电组织细胞外液(ECF)的体积变化。结果显示,在5分钟站立时间间隔内,所有残余肢体的ECF量均减少。在站立间隔后立即步行5分钟期间,健康受试者的剩余肢体的ECF量增加,而患病受试者的肢体减少,其中一名患有周围血管疾病,另一名患有心血管功能不全且高盐摄入。一名受试者在术后翻修后12个月的站立和行走过程中表现出的绝对值ECF量变化少于六个月。向患者呈现生物阻抗数据可改善对医生建议和患者理解的依从性。结果对临床评估,患者教育和治疗决策很有帮助。